HOUSTON, TX —
OSHA Inspection: TEJAS ELECTRICAL ENCLOSURES MFG, INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TEJAS ELECTRICAL ENCLOSURES MFG, INC in 1420 TELEPHONE ROAD, HOUSTON, TX 77023 (NAICS 335932). OSHA activity number 339573388.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEJAS ELECTRICAL ENCLOSURES MFG, INC
- Site address
- 1420 TELEPHONE ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77023
- Mailing
- 1420 TELEPHONE ROAD, HOUSTON, TX 77023
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335932
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.107 B05 IV
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $1,440 · Current $864 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) At the facility, where the spray booth was not equipped with automatic sprinklers. Employees use the spray booth to apply powder coating to metal parts.
Recent events (2)
- — I (S) $864
- — Z (S) $1440
1910.107 D03
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $1,080 · Current $648 Reduced
General-duty citation text
29 CFR 1910.107(d)(3): Each spray booth did not have an independent exhaust duct system discharging to the exterior of the building: a) At the facility, where the spray booth exhaust system discharged into the interior of the building.
Recent events (2)
- — I (S) $648
- — Z (S) $1080
1910.134 C02 I
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $1,080 · Current $648 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) At the facility, where the employees were not provided with the information contained in Appendix D prior to permitting employees to use a 3M full face respirator during powder coating operations. b) At the facility, where the employees were not provided with the information contained in Appendix D prior to permitting employees to use a Miller half-face respirator during welding activities.
Recent events (2)
- — I (S) $648
- — Z (S) $1080
1910.134 C02 II
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) At the facility, where the employer did not establish and implement a respiratory protection program prior to permitting employees to use a 3M full face respirator during powder coating operations. b) At the facility, where the employer did not establish and implement a respiratory protection program prior to permitting employees to use a Miller half-face respirator during welding activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At the facility, where the employer did not provide a medical evaluation prior to permitting employees to use a 3M full face respirator during powder coating operations. b) At the facility, where the employer did not provide a medical evaluation prior to permitting employees to use a Miller half-face respirator during welding activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $1,080 · Current $648 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) At the facility, where the employer did not develop and implement a hazard communication program. The employer uses chemicals such as, but not limited to, Powdura powder coating, containing triglycidyl isocyanurate, a mutagen.
Recent events (2)
- — I (S) $648
- — Z (S) $1080
1910.1200 G08
- Issued
- Jun 11, 2014
- Abate by
- Jul 12, 2014
- Penalty
- Initial $1,080 · Current $648 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required safety data sheets (SDSs) for each hazardous chemical in the workplace: a) At the facility, where the employer did not maintain a copy of the SDS for the Argon compressed gas which is used to perform welding activities.
Recent events (2)
- — I (S) $648
- — Z (S) $1080
More inspections at Tejas Electrical Enclosures MFG, INC
View Tejas Electrical Enclosures MFG, INC's full OSHA safety record →
More inspections in this industry (NAICS 335932)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339573388.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.