OSHA Inspection: J.R. RAMON & SONS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of J.R. RAMON & SONS, INC. in 903 N ST. MARY'S ST, SAN ANTONIO, TX 78207 (NAICS 238910). OSHA activity number 339574170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.R. Ramon & Sons, INC. — free Get an email when a new federal OSHA severe-injury report for J.R. Ramon & Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
903 N ST. MARY'S ST
City
SAN ANTONIO
State
TX
ZIP
78207
Mailing
1325 FRIO CITY ROAD, SAN ANTONIO, TX 78226
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
60
Ownership type
A

12 citations on file for this inspection.

1926.1101 E01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(e)(1): All Class I, II, and III asbestos work was not conducted within regulated areas:       The YMCA Building, old gym:  On or about January 13, 2014, a two layered wall consisting of concrete masonry unit (CMU) on the interior contained asbestos weatherproofing material was demoed and removed in the open area of the gym and not in containment exposing employees to class II asbestos.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 F01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(f)(1)(i): Where exposure monitoring was required under 29 CFR 1926.1101, the employer did not perform monitoring to determine accurately the airborne concentrations of asbestos to which employees were or potentially were exposed:       The YMCA Building, old gym:  On or about January 13, 2014, when class II asbestos containing weatherproofing material was disturbed and cut into the employer did not conduct any air sampling exposing employees to asbestos hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 F02 I

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9020

29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace:       The YMCA Building, Old gym:  On or about January 13, 2014, when class II asbestos containing weatherproofing material was disturbed by demolition and removal the employer did not ensure that air sampling was conducted by an competent person exposing employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1101 G01

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(g)(1): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of the exposure:      The YMCA Building, old gym:  On or about January 13, 2014, when class II asbestos containing weatherproofing material was demoed, removed, and hauled off the employer did not use:  HEPA filtration vacuum cleaners to clean the debris, enclosures or isolation of the work area, local exhaust ventilation containing HEPA filtration, wet methods, or proper cleanup and waste disposal exposing employee to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 G07 I

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(g)(7)(i): All Class II work was not supervised by a competent person as defined in 29 CFR 1926.1101(b):            The YMCA building, old gym:  On or about January 13, 2014, when class II asbestos containing weatherproofing material was demoed, removed, and hauled off there was no asbestos competent person supervising the work exposing employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 H01 II

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(h)(1)(ii): Respirators were not used during Class II work where asbestos containing material was not removed in a substantially intact state:       The YMCA Building, old gym:  On or about January 13, 2014, CMU containing class II asbestos weatherproofing material was demoed, removed, and hauled away the employer did not ensure that employees wore respirators exposing employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 I01

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos that exceed the time weighted average and/or excursion limit in 29 CFR 1926.1101(c) or for which a required negative exposure assessment was not produced:       The YMCA Building, old gym:  On or about January 13, 2014, when CMU containing class II asbestos weatherproofing material was demoed, removed, and hauled away the employer did not ensure that employees wore protective clothing and a negative exposure assessment was not conducted exposing employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 K03 I

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $4,900 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(k)(3)(i):  Before the employer permitted its own employees to perform work subject to this standard in areas or adjacent to areas containing asbestos-containing material (ACM) and presumed asbestos-containing material (PACM), the employer did not identify the presence, location and quantity of asbestos containing material and/or presumed asbestos containing material therein pursuant to 29 CFR 1926.1101(k)(1):       The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 exposing employees of the subcontractor to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $4900
  • — Z (S) $4900

1926.1101 K03 II B

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9020

29 CFR 1926.1101(k)(3)(ii)(B): The employer did not inform employers of employees who worked and/or were working in adjacent areas of the location and quantity of asbestos containing material and/or presumed asbestos containing material present in the area:       a)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify its employees of the asbestos containing building material in the exterior wall.       b)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify Texas Cutting & Coring employees of the asbestos containing building material in the exterior wall.          c)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify Beyer Mechanical employees of the asbestos containing building material in the exterior wall.         d)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify Automatic Fire Protection employees of the asbestos containing building material in the exterior wall.        e)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify FAK Painting employees of the asbestos containing building material in the exterior wall.         f)  The YMCA Building, old gym:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc., demolition contractor did not identify asbestos containing weatherproofing material behind CMU and did not consider this material presumed asbestos containing material for a building constructed in 1973 and did not notify Cappadonna Electric employees of the asbestos containing building material in the exterior wall.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1101 K04

Deleted Serious Gravity 10 5 instances 23 exposed
Issued
Jul 7, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9020

29 CFR 1926.1101(k)(4): Employer who discovered asbestos containing material and/or presumed asbestos containing material on a worksite did not convey information concerning the presence, location and quantity of such newly discovered asbestos containing material and/or presumed asbestos containing material to the owner and to other employer of employees working at the worksite within 24 hours of discovery:            a)  The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc. did not inform Texas Cutting & Coring of the presence, location, and quantitiy of ACM of newly discovered asbestos containing material (ACM) at the worksite within 24 hours of discovery.       b)  The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc. did not inform Beyer Mechanical of the presence, location, and quantitiy of ACM of newly discovered asbestos containing material (ACM) at the worksite within 24 hours of discovery.         c)  The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc. did not inform Automatic Fire Protection of the presence, location, and quantitiy of ACM of newly discovered asbestos containing material (ACM) at the worksite within 24 hours of discovery.        d)  The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc. did not inform FAK Painting of the presence, location, and quantitiy of ACM of newly discovered asbestos containing material (ACM) at the worksite within 24 hours of discovery.       e  The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 13, 2014 and at times prior to, J.R. Ramon & Sons, Inc. did not inform Cappadonna Electric of the presence, location, and quantitiy of ACM of newly discovered asbestos containing material (ACM) at the worksite within 24 hours of discovery.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1101 K09 IV C

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Abate by
Jul 24, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(k)(9)(iv)(C): For Class II operations not involving the categories of material specified in 29 CFR 1926.1101(k)(9)(iv)(A), training was not provided which at a minimum included all the elements in 29 CFR 1926.1101(k)(9)(vii) and in addition the specific work practices and engineering controls of 29 CFR 1926.1101(g), and did not include "hands-on" training in the work practices applicable to each category of material that the employee would remove and each removal method that the employee would use":       The YMCA Building, old gym:  On or about January 13, 2014, when concrete masonry unit (CMU) containing class II asbestos weatherproofing material was demoed, removed, and hauled away the employer did not train employees prior to disturbing the CMU exposing the employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1926.1101 O01

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 7, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 9020

29 CFR 1926.1101(o)(1): General. On all construction worksites covered by this standard, the employer shall designate a competent person, having the qualifications and authorities for ensuring worker safety and health required by Subpart C, General Safety and Health Provisions for Construction (29 CFR 1926.20 through 1926.32).            The YMCA building, old gym:  On or about January 13, 2014, when class II asbestos containing weatherproofing material was demoed, removed, and hauled off there was no competent person to supervise and ensure worker safety and health for work containing asbestos materials exposing employees to asbestos inhalation.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

View J.R. Ramon & Sons, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339574170.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.