Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RECLA METALS LLLP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RECLA METALS LLLP in 136 S. MAPLE, MONTROSE, CO 81401 (NAICS 423930). OSHA activity number 339574774.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Recla Metals Lllp — free Get an email when a new federal OSHA severe-injury report for Recla Metals Lllp is published. One employer, no account, unsubscribe in one click.
Establishment
RECLA METALS LLLP
Site address
136 S. MAPLE
City
MONTROSE
State
CO
ZIP
81401
Mailing
136 S. MAPLE, MONTROSE, CO 81401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
32
Ownership type
A

20 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $2,380 · Current $1,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the insulation of the electrical connections for an electromagnet lifting device was torn and in need of repair:    (a)  On or about January 27, 2014, and at times prior, the employer did not protect employees from falling and flying scrap metal from the magnet attached to a hook in the middle of the grapple on the Liebherr 904 material handler, which had the insulation of its electrical cord torn ripped and torn exposing the conductors inside.  The magnet was used to clean the area of scrap metal in close proximity to workers on the ground and operating other machinery during the clean-up activity.  Were the electrical connection to fail during a lift, the material would fall or be flung off of the magnet.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2380

1910.106 E06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:    (a) On or about January 27, 2014, and at times prior, the employer did not ensure that employees were protected from fire and explosion hazards under the automobile stand when they puncture automobile fuel tanks with a chisel that was not non-sparking.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 4, 2014
Abate by
May 21, 2014
Penalty
Initial $2,975 · Current $1,500 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) On or about January 27, 2014, and at times prior, the employer did not provide a lockout/tag out program for employees who service and maintain equipment including but not limited to the balers, material handlers, and diesel fuel dispensers.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2975

1910.147 C05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified:  (a) On or about January 27, 2014, and at times prior, the lock used to lockout the electrical box powering the diesel fuel pump was not identified as a specific lockout device.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) On or about January 27, 2014, and at times prior, the employer exposed employees to corrosive hazards in that there was no eye wash station in the area where employees handled used vehicle batteries.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.212 A01

Serious Gravity 5 2 instances 6 exposed
Issued
Apr 4, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,975 · Current $1,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  On or about January 27, 2014, and at times prior, operators of the alligator shear and the half shear in the non-ferrous garage, and operators of the alligator sheer under the shed next to the blue Marathon baler, were not protected from amputation hazards in that the machines were not guarded during use.      (b)  On or about January 27, 2014, and at times prior, operators were not protected from amputation and crushing hazards from the following balers whose guards did not operate when the bailers were operating:      1) General Hydraulics, brown, in the non-ferrous area.      2) Loadking, green, non-ferrous area.      3) The baler adjacent from the can machine outside of the garage in the non-ferrous area.      4) Marathon, blue, south-facing, south of the side stroke baler.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2975

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a)  On or about January 28, 2014, and at times prior, operators of the AccurPress 725012 press break in the fabrication area were exposed to amputation hazards when bending metal because the machine is not guarded and the employees are not restrained from accessing the point of operation.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  (a)  On or about January 27, 2014, and at times prior, the employer did not ensure employees were protected from the hazard of a broken abrasive wheel in that the work rest on the grinder in the non-ferrous area was missing.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(2): Maximum permissible exposure angle(s) for the grinding wheel periphery or side(s) of abrasive wheel machinery were exceeded:  (a)  On or about January 27, 2014, and at times prior, the employer did not ensure employees were protected from the hazard of a broken abrasive wheel in that grinder in the non-ferrous area was not guarded.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a)  On or about January 27, 2014, and at times prior, the employer did not ensure employees were protected from the hazard of a broken abrasive wheel in that tongue guard on the grinder in the non-ferrous area was missing.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 4, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a)  On or about January 27, 2014, and at times prior, employees who use the diesel fuel pump are exposed to ingoing nip points an rotating parts from the belt and pully on the pump that is unguarded.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 8 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) On or about January 27, 2014, and at times prior the employer did not protect employees from electrical hazards in that relocatable power taps were used in ways not consistent with their listing and labeling:      1)  The Belkin Surge Master was used outdoors at the can collection and scale area.        2)  A relocatable power tap that was in use was hanging by its own cord instead of being mounted, on the wall adjacent from the plasma cutter operator's station.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.303 F01

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) On or about January 27, 2014, and at times prior, the electrical panel at the south end of the truck shed on the east wall, was not labeled to indicate which equipment the circuits powered.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 8 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  On or about January 27, 2014, and at times prior, the employer did not ensure that employees were protected from fire hazards in that the electrical panels in the following locations were blocked from access by stored items:     1)  Inside the non-ferrous building on the south wall next to the east bay door.     2)  In the truck shed at the south end, the electrical boxes for the baler.     3)  On the east wall of the tubing shed at the north end.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or about January 27, 2014, and at times prior, the employer did not protect employees from electrical hazards in the truck shed in that an energized outlet along the east wall of the truck shed did not have a faceplate.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about January 28, 2014, and at times prior, the employer did not protect employees from electrical hazards in the fabrication area in that wiring to the Krras sheet metal sheer foot petal was not protected with shielding to prevent strain on the wiring at the terminal joints.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 V

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed):  (a) On or about January 27, 2014, and at times prior, the employer did not protect employees from shock hazards in that the outlets along the east wall of the truck shed did not have weatherproof enclosure.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 4, 2014
Abate by
May 21, 2014
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) On or about January 27, 2014, and at times prior the employer had not created and implemented a hazard communications program for employees who come in contact with gasoline, diesel fuel, lubricants, and other toxic, flammable or corrosive materials as referenced in the Recla Metals Safety Program, to include labels, a list of hazardous chemicals at the workplace, safety data sheets, employee information and training, and methods of training for non-routine tasks.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.1200 F05 I

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  (a) On or about January 27, 2014, and at times prior the employer did not ensure employees were aware of the contents of containers that were unlabeled.  The containers, one for used fuel, one for used antifreese, and a diesel fuel tank, were next to the automobile stand, and a spray bottle with a clear liquid in it was next to the plasma cutter.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 4, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  (a) On or about January 27, 2014, and at times prior the employer did not ensure employees were aware of the hazards of the contents of containers that were unlabeled.  The containers, one for used fuel, one for used antifreese, and a diesel fuel tank, were next to the automobile stand, and a spray bottle with a clear liquid in it was next to the plasma cutter.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Recla Metals Lllp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339574774.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.