BRONX, NY ·
OSHA Inspection: R. S ECUA CONTRACTING CORP.
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of R. S ECUA CONTRACTING CORP. in 769 WHITE PLAINS RD., BRONX, NY 10473 (NAICS 236220). OSHA activity number 339575615.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R. S ECUA CONTRACTING CORP.
- Site address
- 769 WHITE PLAINS RD.
- City
- BRONX
- State
- NY
- ZIP
- 10473
- Mailing
- 104-18 34TH AVE., CORONA, NY 11368
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Jun 24, 2014
- Abate by
- Aug 11, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: Location: entire site On or about: 1/31/14 a) Employees were exposed to hazards including unsafe demolition activities, lack of machine guarding and electrical hazards. The employees were not provided with general safety and health training.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.300 B01
- Issued
- Jun 24, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they were not equipped with such guards when in use: location: renovation area on or about: 1/31/14 a) Employees, engaged in renovation work, were using a Ridgid Compound Miter Saw, model R412, to cut wood. The point of operation guard was missing, exposing the metal blade.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.404 B01 I
- Issued
- Jun 24, 2014
- Abate by
- Jul 7, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: renovation area on or about: 01/31/14 a) Employees were using electrical equipment, including a Makita sander, that was plugged into extension cords. The employees were not provided with GFCI protection or an assured equipment grounding conductor program.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.404 F06
- Issued
- Jun 24, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: renovation area on or about: 01/31/14 a) Employees were using an extension cord to power electrical equipment, including a Ridgid abrasive cut-off machine. The extension cord was missing a grounding pin.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.405 G02 III
- Issued
- Jun 24, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Splices. Flexible cords were not used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger were not repaired so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced: location: renovation area on or about: 01/31/14 a) Employees were using a spliced extension cord to power electrical equipment, including a Ridgid abrasive cut-off machine. The cord used for the splice did not have a grounding wire or pin and did not have the outer sheath properties of the original cord. Additionally, there was approximately two inches of the inner wires exposed.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.405 B01
- Issued
- Jun 24, 2014
- Abate by
- Jul 7, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed. Unused openings in cabinets, boxes, and fittings also were not effectively closed: location: renovation area on or about: 1/31/14 a) Employees were using a duplex outlet that was no longer attached to metal conduit to energize electrical equipment, including a Ridgid abrasive cut-off machine. The wires going from the conduit to the duplex outlet were not protected from abrasion.
Recent events (3)
- · F (S) $1000
- · C (S) $2000
- · Z (S) $2000
1926.501 C
- Issued
- Jun 24, 2014
- Abate by
- Jul 7, 2014
- Penalty
- Initial $7,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.501(c): When employees were exposed to falling objects, the employer did not implement one of the following measures; -1 Erect toeboards, screens, or guardrail systems to prevent objects from falling from higher levels; or, -2 Erect a canopy structure; or -3 Barricade the area to which objects could fall, prevent employees from entering the barricaded area, and keep objects away from the edge of the higher level: location: renovation area on or about: 1/10/14 a) Employees, engaged in commercial renovation activities, were working in the vicinity of an air conditioning condenser that was being removed from the ceiling. Measures were not taken to protect the employees from being struck by the condenser.
Recent events (3)
- · F (S) $4000
- · C (S) $7000
- · Z (S) $7000
1926.1053 B08
- Issued
- Jun 24, 2014
- Abate by
- Jul 7, 2014
- Penalty
- Initial $7,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder: location: renovation area on or about: 1/10/14 a) An employees was standing on a 10' metal A-frame ladder while removing an air conditioning condenser. The ladder was not secured nor was the area barricaded.
Recent events (3)
- · F (S) $4000
- · C (S) $7000
- · Z (S) $7000
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339575615.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.