OSHA Inspection: D. T. A. ELECTRIC, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of D. T. A. ELECTRIC, INC. in 1348 GENOA RED BLUFF, HOUSTON, TX 77034 (NAICS 238210). OSHA activity number 339576472.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D. T. a. Electric, INC. — free Get an email when a new federal OSHA severe-injury report for D. T. a. Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1348 GENOA RED BLUFF
City
HOUSTON
State
TX
ZIP
77034
Mailing
4321 SHERWOOD LANE, HOUSTON, TX 77092
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
25
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Apr 18, 2014
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, were not approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.  Building A; receptacle outlets did not have ground-fault circuit interrupters on temporary wiring for personnel protection, exposing employees and subcontract employees to electrical hazards.
Recent events (1)
  • — Z (S) $1020

1926.405 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 18, 2014
Abate by
Apr 18, 2014
Penalty
Initial $867 · Current $867
29 CFR 1926.405(b)(2): Covers and canopies. All pull boxes, junction boxes, and fittings were not provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box did not have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   Building C; the employer did not insure that the receptacle outlets were provided with covers, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $867

View D. T. a. Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339576472.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.