WASHINGTON, DC —
OSHA Inspection: C. S. R. CONTRACTING SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C. S. R. CONTRACTING SERVICES in 2701 WISCONSIN AVE, NW, WASHINGTON, DC 20007 (NAICS 238130). OSHA activity number 339577108.
Where did this inspection happen?
- Establishment
- C. S. R. CONTRACTING SERVICES
- Site address
- 2701 WISCONSIN AVE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20007
- Mailing
- 7908 KENNEWICK AVE, #102, TAKOMA PARK, MD 20912
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) South Side of the Building, Ground Level - An employee was observed without head protection while standing under a roof truss that was being hoisted exposing him to a potential head injury, on or about 02/06/14.
Recent events (1)
- — Z (S) $1200
1926.150 C01 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a) First Floor of the Building - Fire extinguishers were not provided on each floor of the building including on the 1st floor where a diesel All-Pro Series 170T heater was in use exposing the carpenters to a potential fire hazard, on or about 02/06/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $1200
1926.451 E01
- Issued
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross-braces were used as a means of access: a) 2nd Floor South Wall of the Building - Carpenters were observed standing on carpenter pole scaffolds which were not provided with ladder access exposing them to 6 foot fall hazard, on or about 02/06/14.
Recent events (1)
- — Z (S) $1200
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) First Floor of the Building - Carpenters were observed standing on carpenter pole scaffolds which were not protected with fall protection while leaning over the exterior wall hoisting roof trusses exposing them to a 28 foot fall hazard, on or about 02/06/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2000
1926.501 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 2nd Floor East Side of the Building - A carpenter were observed without fall protection while guiding a roof truss in to place near an unguarded wall opening exposing him to a 19 foot fall hazard, on or about 02/06/14. b) 2nd Floor South Wall of the Building - A carpenter was observed without fall protection while sitting on top of the exterior wall exposing him to a 28 foot fall hazard, on or about 02/06/14.
Recent events (1)
- — Z (S) $0
1926.1051 A
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) 2nd Floor South Wall of the Building - A carpenter was observed climbing from the scaffold deck onto the top of the exterior wall which was 34 inches above the scaffold decking, on or about 02/06/14.
Recent events (1)
- — Z (S) $2000
1926.1053 B01
- Issued
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Between the 1st & 2nd Floor of the Building - Carpenters were observed using an extension ladder which only extended 2 rungs past the 2nd floor exposing them to a 9 foot fall hazard, on or about 02/06/14.
Recent events (1)
- — Z (S) $1200
1926.1053 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Between the Basement & 1st Floor of the Building - Carpenters were observed using a 8 foot step ladder as access between floors and stepping on top rung exposing them to an 8 foot fall hazard, on or about 02/06/14.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339577108.