OSHA Inspection: SALGADO CONCRETE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SALGADO CONCRETE in 2601 BELFORD, GRAND JUNCTION, CO 81501 (NAICS 238170). OSHA activity number 339577702.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salgado Concrete for free Get an email when a new federal OSHA severe-injury report for Salgado Concrete is published. One employer, no account, unsubscribe in one click.
Establishment
SALGADO CONCRETE
Site address
2601 BELFORD
City
GRAND JUNCTION
State
CO
ZIP
81501
Mailing
766 23 1/2 RD, GRAND JUNCTION, CO 81501
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
Private (A)

7 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section:      (a)       Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, the employer did not ensure that the supported scaffold was designed by a qualified person, in that the scaffold wood platform was constructed at the job site by non qualified personnel. A skid steer was used to elevate an employee approximately 15 feet on a job made scaffold in order to perform siding work. This condition exposed the employee to a fall hazard of approximately 15 feet.      Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7): The scaffold was erected, moved, dismantled, or altered without the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration:     (a)  Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501: On or before January 28, 2014 the employer did not ensure that the scaffold being used onsite was erected by a competent person.      Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.       (a)           Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, employees were accessing the scaffolding without the use of a ladder. This condition exposes employees to fall hazards.        Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2014
Abate by
Mar 14, 2014
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(g)(1):  Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level:          (a)        Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, the exposing employer did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platform of the scaffolding. This condition exposed employees to a fall of approximate 15 feet.      Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2800

1926.454 A

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.454(a):  The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards:       (a)     Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, the exposing employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedure(s) to control or minimize those hazards. Employees were conducting siding operations on a job made scaffold. This condition exposed the employees to a fall of approximately 15 feet due to recognizing the hazards of working on the scaffold.       Abatement Note: The training shall include the following elements at a minimum:       (1)  The nature of any electrical hazards, fall hazards, and falling object hazards in the work area;       (2)  The correct procedures for dealing with electrical hazards and for erecting, maintaining, and disassembling the fall protection systems and falling object protection systems being used:       (3)  The proper use of the scaffold, and the proper handling of materials on the scaffold;       (4)  The maximum intended load and the load-carrying capacities of the scaffold used; and       (5)  Any other pertinent requirements of this subpart.       Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1200

1926.501 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.     (a)   Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, did not ensure that employees working at a height greater than 6 feet were provided with an adequate personal fall arrest system. Employees were working on the roof of a shed without the use of fall protection.       Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1600

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2014
Abate by
Mar 19, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:      (a)    Salgado Concrete, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, the employer was allowing employees to use a ladder inadequately. Employees were seen using a ladder on the roof of the shed in order to conduct siding operations. The ladder was an A frame ladder being used in its collapsed position.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").