Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: MID STATES ELECTRIC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MID STATES ELECTRIC in 1131 DAKOTA AVE OC-90, DAKOTA CITY, NE 68731 (NAICS 238210). OSHA activity number 339578320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MID States Electric — free Get an email when a new federal OSHA severe-injury report for MID States Electric is published. One employer, no account, unsubscribe in one click.
Establishment
MID STATES ELECTRIC
Site address
1131 DAKOTA AVE OC-90
City
DAKOTA CITY
State
NE
ZIP
68731
Mailing
1658 HWY 20, SIOUX CITY, IA 51106
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

1 citation on file for this inspection.

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
May 14, 2014
Abate by
Jul 1, 2014
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1926.454(a):     The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.    At the Tyson Food Facility new kill floor construction project the employer is failing to ensure that employees who operate the articulating boom lift are provided training in accordance with this subpart.  Specifically the employees operating a Gene Z-30 Articulating Boom.  The Gene Z-30 was provided by the employer for use by employees without providing or ensuring training had been given on this equipment.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

View MID States Electric's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339578320.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.