Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAHNEL BROTHERS COMPANY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAHNEL BROTHERS COMPANY INC. in COURT STREET, AUGUSTA, ME 04333 (NAICS 238160). OSHA activity number 339579195.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hahnel Brothers Company INC. — free Get an email when a new federal OSHA severe-injury report for Hahnel Brothers Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
COURT STREET
City
AUGUSTA
State
ME
ZIP
04333
Mailing
46 STRAWBERRY AVENUE, LEWISTON, ME 04243
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.150 C01 VI

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 13, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, shall be provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles.    Jobsite:      Employees using (2) two 100 lbs tanks of propane on the roof with no fire extinguisher present.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.405 B02

Other-than-serious 1 instance 6 exposed
Issued
Feb 13, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.405(b)(2): Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    Jobsite:    Employees on site were exposed to eletrcal shock hazards for not inspecting or installing covers on metal outlet extension cords on site.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

View Hahnel Brothers Company INC.'s full OSHA safety record →