Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ORACLE BUILDERS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ORACLE BUILDERS, LLC. in 513-515 C STREET, NE, WASHINGTON, DC 20002 (NAICS 236117). OSHA activity number 339579278.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oracle Builders, LLC. — free Get an email when a new federal OSHA severe-injury report for Oracle Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
513-515 C STREET, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
407 OAK KNOLL DRIVE, ROCKVILLE, MD 20850
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
14
Ownership type
A

13 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 15, 2014
Penalty
Initial $2,000 · Current $1,240 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part:     a) Job Site - Employer had not developed or implemented a safety and health program as evidenced by hazards such as but not limited to; falls, electrical and lack of personal protective equipment, on or about 02/07/2014.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1240
  • — Z (S) $2000

1926.21 B02

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a) Job Site - Employees were not provided adequate hazard recognition training as evidenced by hazards such as but not limited to;  electrical and not using personal protective equipment, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Job Site - Employees were not provided adequate training on the recognition and avoidance of fall hazards such as but not limited to; standing on a flat roof with no protection exposed to a 29' 3" fall ,  kneeling at the edge of a plywood deck with only one guardrail, exposed to a 36' fall hazard, and using a job made plywood ramp missing a guardrail and exposed to a 10' fall hazard, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1060 A

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a) Job Site - Employees were not provided adequate training on ladder usage as evidenced by hazards such as but not limited to; using a ladder that did not extend at least 3' above an upper landing , a ladder not set at the correct degree angle, a ladder with cracked or broken rungs, and a ladder not designed for usage, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.95 A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2014
Penalty
Initial $2,000 · Current $1,240 Reduced
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact:    a) Unit 515, Third Floor Rear - An employee was observed attaching a plywood sheet to wooden floor joists using a pneumatic nail gun and not wearing eye protection, on or about 02/07/2014.
Recent events (2)
  • — I (S) $1240
  • — Z (S) $2000

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2014
Penalty
Initial $1,600 · Current $992 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) Unit 513, Second Floor - Employees without head protection were observed standing below an employee installing wooden blocks on top of a framed wall, on or about 02/07/2014.
Recent events (2)
  • — I (S) $992
  • — Z (S) $1600

1926.405 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 27, 2014
Penalty
Initial $1,600 · Current $992 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    a) Unit 513, Second Floor - An employee was using a DeWalt drill motor to bolt up a 2X10 inch wood framing member to a concrete block wall and the cord on the drill was spliced, 110 volt, 15 amp service, on or about 02/07/2014.
Recent events (2)
  • — I (S) $992
  • — Z (S) $1600

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) Unit 513, Second Floor - An employee was using a DeWalt drill motor to bolt a 2X10 wooden framing member to a concrete block wall and the outer insulaton on the cord was torn allowing conductors to be exposed, 110 volt, 15 amp service, on or about 02/07/2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 3 instances 8 exposed
Issued
Mar 27, 2014
Penalty
Initial $2,800 · Current $1,736 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) First Floor, Front Entrance - Employees were observed using a 25" wide ramp to gain access to the first floor and the guardrail was missing, exposing employees to a 10' fall hazard, on or about 02/07/2014.    b) Unit 513, Second Floor, West Wall - A carpenter was observed standing on an adjoining rowhouse flat roof plumbing up a wood framed wall without using fall protection and exposed to a 29' 3" fall hazard, on or about 02/07/2014.    c) Unit 515, Third Floor, Rear Wall - An employee was observed kneeling down to pick up a sheet of plywood at the floor edge and the guardrail height was set up at 49 1/2", exposing employee to a 36' fall hazard, on or about 02/07/2014.
Recent events (2)
  • — I (S) $1736
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 2 instances 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,400 · Current $1,488 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) First Floor, Front Entrance - Employees were observed using a portable jobmade ladder to gain access to an access ramp and the ladder rails only extended 6" above the landing surface, exposing the employees to a 6 ft, fall, on or about 02/07/2014.    b) Unit 513, Between First and Second Floors - Employees observed using a portable metal ladder to gain access to the second floor and the ladder rails only extended 23" above the landing surface were exposed to an 11' fall hazard, on or about 02/07/2014.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1488
  • — Z (S) $2400

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 27, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Unit 513 Between First and Second Floors - Employees were using a portable metal ladder to gain access to an upper level and the ladder feet were at the top end of the ladder, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B05 I

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:  a) First Floor Front Entrance - Employees were observed using a jobmade portable wood ladder to gain access to a ramp,and the ladder was set at a 45 degree angle, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 2 instances 8 exposed
Issued
Mar 27, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired:   a) Unit 513, Between First and Second Floors - Employees were observed using a portable metal ladder to gain access to an upper floor, and a rung was partiallly cut through which effected the structural stability of the ladder, on or about 02/07/2014.   b) Unit 515, Between First and Second Floors - Employees were observed using a portable metal ladder to gain access to an upper floor and the top rung of the ladder was completly broken in half, which effected the structural stability of the ladder, on or about 02/07/2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Oracle Builders, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339579278.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.