Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTROLUX HOME CARE PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELECTROLUX HOME CARE PRODUCTS, INC. in 9600 PAN AMERICAN DR., EL PASO, TX 79927 (NAICS 443111). OSHA activity number 339579823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electrolux Home Care Products, INC. — free Get an email when a new federal OSHA severe-injury report for Electrolux Home Care Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9600 PAN AMERICAN DR.
City
EL PASO
State
TX
ZIP
79927
Mailing
10200 DAVID TAYLOR DR., CHARLOTTE, NC 28262
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
443111
Employees
107
Ownership type
A

3 citations on file for this inspection.

1910.305 G02 III

Serious Gravity 5 1 instance 12 exposed
Issued
Jun 10, 2014
Abate by
Jun 20, 2014
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.    on or about February 07, 2014, and times prior thereto, employees were using an energized dock light fixture at dock #40 in the shipping area that had damaged strain relief. The outer jacket was damaged and torn, exposing internal conductors to damage, and exposing employees to electrical shock and fire hazards.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.334 A03 I

Serious Gravity 5 1 instance 12 exposed
Issued
Jun 10, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor.  On or about February 07, 2014, and times prior thereto, employees used a dock light that was not equipped with an equipment grounding conductor, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 B01

Other-than-serious 1 instance 107 exposed
Issued
Jun 10, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.  On or about February 07, 2014, and times prior thereto, aisle and passageway by electrical panels were not kept clean and in good repair as to not create a hazard.  This condition exposed employees to tripping and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Electrolux Home Care Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339579823.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.