Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ZIEGLER LUMBER COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ZIEGLER LUMBER COMPANY in 1109 WARNER AVE., LEWISTON, ID 83501 (NAICS 444110). OSHA activity number 339579864.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ziegler Lumber Company — free Get an email when a new federal OSHA severe-injury report for Ziegler Lumber Company is published. One employer, no account, unsubscribe in one click.
Site address
1109 WARNER AVE.
City
LEWISTON
State
ID
ZIP
83501
Mailing
1109 WARNER AVE., LEWISTON, ID 83501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
23
Ownership type
A

3 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 14, 2014
Abate by
Apr 24, 2014
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a)  In the warehouse: On February 4, 2014, and at times prior thereto, employees were exposed to electrolyte (battery acid) splash and hydrogen gas when filling the Yale electric forklift battery and charging it in the warehouse without benefit of eye or face protection.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.151 C

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 14, 2014
Abate by
Jun 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a)  In the warehouse: On February 4, 2014, and at times prior thereto, employees were exposed to electrolyte splash and hydrogen gas when filling the Yale electric forklift battery and charging it in the warehouse 45 feet or more from any water source.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Other-than-serious 1 instance 5 exposed
Issued
Apr 14, 2014
Abate by
Apr 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  In the lumber yard: On February 4, 2014, and at times prior thereto, employees were exposed to potential electrical shock hazards when using the Hitachi 10 inch chop saw that was powered by extension cords fastened to the Cinder block wall in lieu of permanent fixed wiring of the structure.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ziegler Lumber Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339579864.