OSHA Inspection: KIMBALL ELECTRONICS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KIMBALL ELECTRONICS in 13750 REPTRON BLVD, TAMPA, FL 33626 (NAICS 334419). OSHA activity number 339580771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kimball Electronics — free Get an email when a new federal OSHA severe-injury report for Kimball Electronics is published. One employer, no account, unsubscribe in one click.
Establishment
KIMBALL ELECTRONICS
Site address
13750 REPTRON BLVD
City
TAMPA
State
FL
ZIP
33626
Mailing
13750 REPTRON BLVD, TAMPA, FL 33626
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
230
Ownership type
A

1 citation on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 12, 2014
Abate by
Mar 26, 2014
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a)  for employees operating the Cambridge Automatic Bench Staking Press (Model # AE 2000, Serial # 3506) located  in the Mechanical Assembly Area, as observed on or about, 02/10/14.  In that the press was inadequately guarded (the ring guard was improperly adjusted) allowing the operator's hands/fingers into the point of operation.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3400