AMHERST, NY ·
OSHA Inspection: NATIONAL ELECTRIC COMMUNICATIONS SOLUTIONS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL ELECTRIC COMMUNICATIONS SOLUTIONS INC. in 742 NIAGARA FALLS BOULEVARD, SPACE # 545, AMHERST, NY 14226 (NAICS 238310). OSHA activity number 339580839.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL ELECTRIC COMMUNICATIONS SOLUTIONS INC.
- Site address
- 742 NIAGARA FALLS BOULEVARD, SPACE # 545
- City
- AMHERST
- State
- NY
- ZIP
- 14226
- Mailing
- 144 VILLAGE LANDING, SUITE 304, FAIRPORT, NY 14450
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- Feb 19, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about 2/10/14, at the Boulevard Mall, Space # 545 under renovation for a "Justice" store, 742 Niagara Falls Blvd.,Amherst, NY: A metal 2-receptacle, 120 volt-ac outlet box attached to a flexible metalic conduit was laying on the concrete floor in the building. A Relocatable Power Tap (strip) was plugged into a receptacle in that box and through a series of extension cords supplied power to a Ridgid Abrasive Wheel Cut-Off Saw. The use of the unmounted box laying on the floor is prohibited by the National Electric Code, and the Relocatable Power Tap (strip) is not listed for use on construction sites. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1020
1926.404 F06
- Issued
- Feb 19, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 2/10/14, at the Boulevard Mall, Space # 545 under renovation for a "Justice" store, 742 Niagara Falls Blvd.,Amherst, NY: Employee used a Ridgid Abrasive Wheel Cut-Off Saw, Model # CM14500, to cut metal studs. The Cut-Off saw was connected to 120 volt-ac power via a series of two extension cords, the first of which was Relocatable Power Tap (strip) plugged into a receptacle of a 2-receptacle outlet box laying on the floor. The plug on the power cord of the saw lacked a ground prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1020
1926.451 G01 VII
- Issued
- Feb 19, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) On or about 2/10 14, at the Boulevard Mall, Space # 545 under renovation for a "Justice" store, 742 Niagara Falls Blvd.,Amherst, NY: Employee was exposed to a potential fall from the elevated platform of a JLG Scissors Lift while pulling wires in the ceiling. The employee was standing on the midrail of the lift platform and additionally, the midchain on the entry end of the platform was not fastened. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- · Z (S) $1020
More inspections at National Electric Communications Solutions INC.
View National Electric Communications Solutions INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339580839.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.