OSHA Inspection: USDA FOREST SERVICE - CLEVELAND NF

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USDA FOREST SERVICE - CLEVELAND NF in EL CHARISO FIRE STATION 32353 ORTEGA HIGHWAY, LAKE ELSINORE, CA 92530 (NAICS 115310). OSHA activity number 339581324.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usda Forest Service - Cleveland NF — free Get an email when a new federal OSHA severe-injury report for Usda Forest Service - Cleveland NF is published. One employer, no account, unsubscribe in one click.
Site address
EL CHARISO FIRE STATION 32353 ORTEGA HIGHWAY
City
LAKE ELSINORE
State
CA
ZIP
92530
Mailing
10845 RANCHO BERNARDO ROAD, SUITE 200, SAN DIEGO, CA 92127
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
10
Ownership type
D

5 citations on file for this inspection.

1910.37 B07

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(7): Each exit sign must have the word "Exit" in plainly legible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three-fourths of an inch (1.9 cm) wide.  Engine bay exits: On or about 29JAN14, exit signs posted had lettering measuring less than the required six inches high.
Recent events (1)
  • — Z (S) $0

1910.157 E02

Repeat Gravity 5 1 instance 10 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) Kitchen: On or about 29JAN14, a fire extinguisher was not inspected monthly.   (b) Engine bay: On or about 29JAN14, a fire extinguisher was not inspected monthly.   The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910. 157(e)(2), which was contained in OSHA inspection number 910625, citation number 1, item number 2, and was affirmed as a final order on July 29, 2013, with respect to a workplace located at 602 S. Tippecanoe Av., San Bernardino, CA 92408.
Recent events (1)
  • — Z (R) $0

1910.253 B04 I

Repeat Gravity 5 1 instance 10 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:   Gas House, On or about 29JAN14, a compressed gas cylinder containing oxygen was stored with road flares and muriatic acid.   The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910. 253(b)(4)(i), which was contained in OSHA inspection number 911912, citation number 1, item number 7, and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 28500 Highway 243, Mountain Center, CA 92561.
Recent events (1)
  • — Z (R) $0

1910.303 B07 I

Repeat Gravity 5 2 instances 10 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  (a) Engine bay East exit: On or about 29JAN14, 120VAC live conductors were exposed to inadvertent employee contact where openings in a switch box was left uncovered, and the cover was not effectively secured.  (b) Engine bay water fountain: On or about 29JAN14, 220VAC live conductors were exposed to inadvertent employee contact where an opening in a switch box was left uncovered.  The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910. 303(b)(7)(i), which was contained in OSHA inspection number 911911, citation number 1, item number 11, and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 41374 North Shore Drive, Fawnskin, CA 92333.
Recent events (1)
  • — Z (R) $0

1910.305 G01 IV A

Repeat Gravity 5 1 instance 5 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure:  Training room: On or about 29JAN14, flexible cords were used for over 90 days one year to provide 120VAC service to a television and VCR.  The USDA Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 911911, citation number 1, item number 15, and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 41374 North Shore Drive, Fawnskin, CA 92333.