ONEONTA, NY —
OSHA Inspection: MOLD A MATIC CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MOLD A MATIC CORPORATION in 147 RIVER ROAD, ONEONTA, NY 13820 (NAICS 326199). OSHA activity number 339582017.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOLD A MATIC CORPORATION
- Site address
- 147 RIVER ROAD
- City
- ONEONTA
- State
- NY
- ZIP
- 13820
- Mailing
- 147 RIVER ROAD, ONEONTA, NY 13820
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 19, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On or about 2/10/2014, Near machine #20: A secondary press located next to Machine #20 was not provided with point of operation guarding. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.303 G02 I
- Issued
- Feb 19, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) On or about 2/10/2014, Newbury Press #3: Exposed energized parts of the thermocouples were not guarded. b) On or about 2/10/2014, Injection Molder #24: Electrical components used to power an auto picker had exposed energized parts. c) On or about 2/10/2014, Injection Molder #25: Electrical components used to power a shaker had exposed energized parts. Abatement certification is required for these items.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.304 G05
- Issued
- Feb 19, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about 2/10/2014, Newbury Press #3: A metal electrical box on the press was not provided with a path to ground. b) On or about 2/10/2014, Injection Molder #25: A metal pneumatic material control box was not provided with a path to ground. Abatement certification is required for these items.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.305 G02 III
- Issued
- Feb 19, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) On or about 2/10/2014, Near Machine #20: A secondary press had cords entering the machine that were not provided with effective strain relief. b) On or about 2/10/2014, Injection Molder #18: Main cord to Molder #18 was not provided with strain relief where the cord entered the machine. c) On or about 2/10/2014, Injection Molder #24: No strain relief was provided for cables powering an auto picker component. Abatement certification is required for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Mold a Matic Corporation
View Mold a Matic Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339582017.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.