Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: RIVERCITY WATERJET, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIVERCITY WATERJET, INC. in 11734 NACOGDOCHES ROAD, SAN ANTONIO, TX 78217 (NAICS 332312). OSHA activity number 339582819.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rivercity Waterjet, INC. for free Get an email when a new federal OSHA severe-injury report for Rivercity Waterjet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11734 NACOGDOCHES ROAD
City
SAN ANTONIO
State
TX
ZIP
78217
Mailing
11734 NACOGDOCHES ROAD, SAN ANTONIO, TX 78217
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
25
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Mar 26, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   In the Welding Bay, On or about February 12, 2014, employees were exposed to amputation hazards when using a Metal Devil, (metal cutting) chop saw, which had a blade guard that did not retract to the closing position after the cut, while employees were cutting rectangular tubes.
Recent events (1)
  • · Z (S) $2800

1910.213 I01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 20, 2014
Abate by
Mar 26, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  In the Foam Bay, On or about February 12, 2014, employees were exposed to amputation hazards when using the Sterling bandsaw which did not have a guard on the unused portion of the saw blade, while employees were cutting small sections from a large foam piece.
Recent events (1)
  • · Z (S) $2800

1910.253 B02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Mar 30, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.253(b)(2)(ii): 29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:   In the Laser Bay, On or about February 12, 2014, employees were exposed to struck-by hazards when two compressed gas cylinders were not secured from falling or knocked over, while employees are working/walking in the area.
Recent events (1)
  • · Z (S) $1200

1910.253 B04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2014
Abate by
Mar 26, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:   Welding Bay, On or about February 12, 2014, employees were exposed to burns when working close to 3 acetylene and 6 oxygen cylinders stored together, while employees are welding fabricated metal.
Recent events (1)
  • · Z (S) $1600

1910.303 G01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2014
Abate by
Mar 30, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  In the Waterjet Bay, On or about February 12, 2014, employees were exposed to shock hazards when the access space in front of H2 electrical panel was blocked by a pallet with almandite garnet bags and scrap metal parts, while working on the air compressor and chilling unit.
Recent events (1)
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339582819.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.