NEW YORK, NY ·
OSHA Inspection: BRIGHTON CONTRACTORS NYC INC
Programmed Other inspection · Safety discipline
At a glance
On , OSHA opened a programmed Other safety inspection of BRIGHTON CONTRACTORS NYC INC in 125 PARK AVE, NEW YORK, NY 10017 (NAICS 238210). OSHA activity number 339582827.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRIGHTON CONTRACTORS NYC INC
- Site address
- 125 PARK AVE
- City
- NEW YORK
- State
- NY
- ZIP
- 10017
- Mailing
- 2538 E 22ND STREET, BROOKLYN NY 11235, BROOKLYN, NY 11235
What kind of inspection was it?
- Inspection type
- Programmed Other (K)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 5
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Mar 21, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked between the front uprights and the guardrail supports: a) The employer erected two 12 ft tall scaffolds for installing a decorative metal curtain along the 25 ft tall wall (18th floor lobby). The scaffold framings were 4 and 5 ft wide but the working platforms were only 20 inches wide, made of plywood nailed to 2by4 wood. Employees were exposed to falling 12 feet. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.451 F07
- Issued
- Mar 21, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(7): The employer did not ensure that scaffolds were erected, moved, dismantled, or altered only under the supervision and direction of a competent and qualified person: a) The employer erected two 12 ft. tall scaffolds for installing a decorative metal curtain along the 25 ft tall wall (18th floor lobby). The scaffolds were not tall enough, did not have safety guardrails and fully planked platforms; employer used wood screwed together without tie wire to secure the connections. Employees were exposed to scaffold collapse hazard and fall hazard. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS CONDITION DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.451 G01
- Issued
- Mar 21, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) though (vii) establish the types of fall protection to be provided to employees on each type of scaffold. Paragraph (g)(2) addresses fall protection for scaffold erectors and dismantlers: a) Employees were exposed to 12 ft fall hazard when working on the two 12 ft tall scaffolds in the 18th floor lobby without guardrails or personal fall protection systems (harness connected to a lifeline). Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION, THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1926.451 G04 I
- Issued
- Mar 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. Guardrail systems were not installed before the scaffold is released for use by employees other than erecting/dismantling crews: a) Two 12 ft tall scaffolds were not provided with guardrails along the work platforms; 18th floor lobby. Employees were exposed to 12 ft fall hazard. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS CONDITION DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $0
1926.454 A
- Issued
- Mar 21, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) The employer had not provided fall protection training to employees who were using 12 ft tall scaffolds without fall protection in the 18th floor lobby. Location: 125 Park Ave, New York, N.Y. On or about 2/10/2014 NOTE: BECAUSE THE EMPLOYER CORRECTED THIS ITEM DURING THE INSPECTION THE EMPLOYER IS NOT REQUIRED TO SUBMIT ABATEMENT CERTIFICATION NOR DOCUMENTATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.