INDEPENDENCE, KS —
OSHA Inspection: MOLDED FIBER GLASS CONSTRUCTION PRODUCTS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MOLDED FIBER GLASS CONSTRUCTION PRODUCTS COMPANY in 1018 W SYCAMORE ST, INDEPENDENCE, KS 67301 (NAICS 326199). OSHA activity number 339583072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOLDED FIBER GLASS CONSTRUCTION PRODUCTS COMPANY
- Site address
- 1018 W SYCAMORE ST
- City
- INDEPENDENCE
- State
- KS
- ZIP
- 67301
- Mailing
- 1018 W SYCAMORE ST, INDEPENDENCE, KS 67301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 19
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 I01
- Issued
- Apr 7, 2014
- Abate by
- Jun 10, 2014
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: Employees engaged in manufacturing activities using the SCMi vertical bandsaw in the wood shop were exposed to struck-by hazards in that approximately 6 inches of the blade was not guarded underneath the bandsaw table
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.147 C06 I
- Issued
- Apr 7, 2014
- Abate by
- Jun 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The machine specific energy control procedures for the following pieces of equipment utilizing multiple energy sources had not been inspected at least annually: a) Air Makeup Column Reconditioning, outside the column reconditioning area to the west, utilizing electrical and gas sources of energy. b) Air Makeup Lamination, outside the lamination area to the east, utilizing electrical and gas sources of energy.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 B
- Issued
- Apr 7, 2014
- Abate by
- Jun 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: The SCMi vertical band saw in the wood shop was not securly anchored.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Molded Fiber Glass Construction Products Company
View Molded Fiber Glass Construction Products Company's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339583072.