Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOLDED FIBER GLASS CONSTRUCTION PRODUCTS COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MOLDED FIBER GLASS CONSTRUCTION PRODUCTS COMPANY in 1018 W SYCAMORE ST, INDEPENDENCE, KS 67301 (NAICS 326199). OSHA activity number 339583072.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Molded Fiber Glass Construction Products Company — free Get an email when a new federal OSHA severe-injury report for Molded Fiber Glass Construction Products Company is published. One employer, no account, unsubscribe in one click.
Site address
1018 W SYCAMORE ST
City
INDEPENDENCE
State
KS
ZIP
67301
Mailing
1018 W SYCAMORE ST, INDEPENDENCE, KS 67301
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
19
Ownership type
A

3 citations on file for this inspection.

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 7, 2014
Abate by
Jun 10, 2014
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  Employees engaged in manufacturing activities using the SCMi vertical bandsaw in the wood shop were exposed to struck-by hazards in that approximately 6 inches of the blade was not guarded underneath the bandsaw table
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.147 C06 I

Other-than-serious 2 instances 2 exposed
Issued
Apr 7, 2014
Abate by
Jun 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   The machine specific energy control procedures for the following pieces of equipment utilizing multiple energy sources had not been inspected at least annually:  a)  Air Makeup Column Reconditioning, outside the column reconditioning area to the west, utilizing electrical and gas sources of energy.  b)  Air Makeup Lamination, outside the lamination area to the east, utilizing electrical and gas sources of energy.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 B

Other-than-serious 1 instance 1 exposed
Issued
Apr 7, 2014
Abate by
Jun 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  The SCMi vertical band saw in the wood shop was not securly anchored.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Molded Fiber Glass Construction Products Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339583072.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.