Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: S. WILLA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of S. WILLA, INC. in 164 OXFORD, KENILWORTH, IL 60043 (NAICS 238130). OSHA activity number 339583452.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S. Willa, INC. for free Get an email when a new federal OSHA severe-injury report for S. Willa, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
S. WILLA, INC.
Site address
164 OXFORD
City
KENILWORTH
State
IL
ZIP
60043
Mailing
530 N. CEDAR ROAD, WOOD DALE, IL 60191
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
Private (A)

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Jun 26, 2014
Abate by
Jul 30, 2014
Penalty
Initial $440 · Current $440
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:     S. Willa, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:     Citation Number                              Item Number                                    Abatement Date  1                                                           1                                                         02/21/2014  1                                                           2                                                         02/21/2014 1                                                           3a                                                       02/21/2014 1                                                           3b                                                       02/21/2014 2                                                            1                                                        02/21/2014 2                                                            2                                                        03/13/2014      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (O) $440

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 14, 2014
Abate by
Feb 21, 2014
Penalty
Initial $1,760 · Current $1,760
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:    a) Employees were exposed to eye injury while operating an electric saw without the eye protection during carpentry work being conducted from the top of a two story of the building under construction.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $1760

1926.404 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Feb 21, 2014
Penalty
Initial $1,760 · Current $1,760
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:        a) Employees were provided with electrical tools and equipment connected by cord and plug to a Powermate 5000 watt portable generator, having 6250 watts of start-up power, without the use of ground fault circuit interrupters or an assured equipment grounding conductor program.          In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $1760

1926.1053 B04

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Feb 21, 2014
Penalty
Initial $2,640 · Current $2,640
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:      b) Employees were exposed to the hazard of falling approximately 10 feet while using a stepladder for access and egress between two points on the second story of the building.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIV ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $2640

1926.1053 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 14, 2014
Abate by
Feb 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) The top step of a stepladder was used as a step when the stepladder was used for access between two points on the second story of the building.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIV ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $0

1926.501 B13

Repeat Gravity 10 4 instances 4 exposed
Issued
Feb 14, 2014
Abate by
Feb 21, 2014
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):        a) Employees were exposed to the hazard of falling while performing carpentry work from the top plate and deck of the second story of the building.    S. Willa, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501 (b)(13) which was contained in OSHA inspection number 929184, citation 1, item 1, and was affirmed as a final order on September 3, 2013, with respect to a worksite located at 409 Pleasant Drive, Schaumburg, Illinois.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • · Z (R) $6160

1926.503 B01

Other-than-serious 4 instances 4 exposed
Issued
Feb 14, 2014
Abate by
Mar 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:    a) The employer did not prepare written certification records related to employee fall protection training.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (O) $0

View S. Willa, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339583452.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.