MIAMI, FL —
OSHA Inspection: SUTTON FERNERIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUTTON FERNERIES INC. in 1950 NW 89 PL, MIAMI, FL 33172 (NAICS 111422). OSHA activity number 339584989.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUTTON FERNERIES INC.
- Site address
- 1950 NW 89 PL
- City
- MIAMI
- State
- FL
- ZIP
- 33172
- Mailing
- P.O. BOX 226800, MIAMI, FL 33222
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111422
- Employees
- 64
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Feb 25, 2014
- Penalty
- Initial $1,785 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a. On or about February 12, 2014, at the receiving area of the above addressed jobsite, employees were exposed to the hazard of falling 4'-4" to a lower level while disposing of waste materials.
Recent events (2)
- — I (S) $1000
- — Z (S) $1785
1910.176 B
- Issued
- Feb 25, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,100 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a. On or about February 12, 2014, at the cooler area of the above addressed jobsite, employees were exposed to a struck by hazard while working in near proximity of racks used for the stacking of boxes frequently used "greens" which were not secured.
Recent events (2)
- — I (S) $1250
- — Z (S) $2100
1910.304 G05
- Issued
- Feb 25, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $2,800 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about February 12, 2014, at the administration's lunch room of the above addressed worksite, a microwave oven (i.e. Sunbeam, Model # MA-6400B2) lacked a ground prong on its attachment plug, exposing employees to an electrical hazard. b. On or about February 12, 2014, at the production's lunch room of the above addressed worksite, a microwave oven (i.e. GE Turntable) lacked a ground prong on its attachment plug, exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $1350
- — Z (S) $2800
1904.32 A04
- Issued
- Feb 25, 2014
- Abate by
- Mar 7, 2014
- Penalty
- Initial $700 · Current $300 Reduced
General-duty citation text
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30: a. On or about February 12, 2014 at the above addressed worksite, the employer failed to post an OSHA-300A for year 2013.
Recent events (2)
- — I (O) $300
- — Z (O) $700
1910.22 D01
- Issued
- Feb 25, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a. On or about February 12, 2014, at the UPC area of the above addressed jobsite, an area over working spaces was used for storage purposes without having load limits posted, exposing employees to a struck by hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.176 C
- Issued
- Feb 25, 2014
- Abate by
- Mar 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage: a. On or about February 12, 2014, at the administration area of the above addressed jobsite, materials were accumulated on the floor space of a storage area, exposing employees to tripping and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sutton Ferneries INC.
View Sutton Ferneries INC.'s full OSHA safety record →
More inspections in this industry (NAICS 111422)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339584989.