OSHA Inspection: HOLLOW METAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HOLLOW METAL, INC. in 5275 CAUSEWAY BLVD, TAMPA, FL 33619 (NAICS 332321). OSHA activity number 339585119.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hollow Metal, INC. for free Get an email when a new federal OSHA severe-injury report for Hollow Metal, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HOLLOW METAL, INC.
Site address
5275 CAUSEWAY BLVD
City
TAMPA
State
FL
ZIP
33619
Mailing
5275 CAUSEWAY BLVD, TAMPA, FL 33619
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
17
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 31, 2014
Abate by
May 15, 2014
Penalty
Initial $1,600 · Current $675 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a)  Throughout Plant  The employer did not establish and implement a written energy control program, on or about, 02/13/14.
Recent events (2)
  • · I (S) $675
  • · Z (S) $1600

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Mar 31, 2014
Abate by
Jun 16, 2014
Penalty
Initial $2,000 · Current $825 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by an inadequately guarded power press and unguarded unsed portion of a press brake.    a) Door Department - Zeh & Hannemann 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14.    b) Spot Welding Area - Niagara 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14.    c) Press Brake Department - Cincinnati Press Brakes 250 Tons (2) Unguarded used portions of press dies, on or about, 02/13/14.
Recent events (2)
  • · I (S) $825
  • · Z (S) $2000

1910.212 A03 II

Serious Gravity 5 6 instances 6 exposed
Issued
Mar 31, 2014
Abate by
Jun 16, 2014
Penalty
Initial $2,000 · Current $825 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Metal Stud Area - Verson All Steel Press Brake - 45 Ton - Serial # 11536-2062-A  Unguarded point of operation, on or about, 02/13/14.    b) Press Brake Department - Cincinnati Press Brakes (2) 250 Tons - Unguarded point of operations, on or about, 02/13/14.    c) Door Department - Lors Machinery Inc. Spot Welder - Model # 140 AR-OV - Serial # 100-6811 - Unguarded point of operation, on or about, 02/13/14.    d) Spotwelding Area - Lors Spot Welder - Serial # 1955864 - Model # 418 Unguarded point of operation, on or about, 02/13/14.    e) Shear Area - Accurshear Shear - Model# 613510 - Serial # 3401 - Inadequately guarded point of operation and an unguarded point of operation behind the shear, on or about, 02/13/14.
Recent events (2)
  • · I (S) $825
  • · Z (S) $2000

1910.219 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 31, 2014
Abate by
May 15, 2014
Penalty
Initial $1,600 · Current $675 Reduced
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a)    a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press  Inadequately guarded flywheel on inside face of machine, on or about, 02/13/14.
Recent events (2)
  • · I (S) $675
  • · Z (S) $1600

1910.217 B04 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 31, 2014
Abate by
May 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(4)(ii): Mechanical power press(es) using full revolution clutches were not provided with a pad with a nonslip contact area firmly attached to the pedal:  a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons  The foot pedal was missing a non-slip pad, on or about, 02/13/14.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.217 B04 III

Other-than-serious 1 instance 1 exposed
Issued
Mar 31, 2014
Abate by
May 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(4)(iii): Pedal return spring(s) of pedal(s) used on mechanical power press(es) using full revolution clutches were not of the compression type, operating on a rod or guided within a hole or tube, or designed to prevent interleaving of sspring coils in the event of breakage:  a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons - The pedal spring was not operating on a rod or guided within a hole or tube and was attached to the press's single stroke mechanism via a string, on or about, 02/13/14.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B01

Other-than-serious 1 instance 1 exposed
Issued
Mar 31, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press  The power powering the press's foot pedal was torn from the grommet allowing for exposed live insulated conductors, on or about, 02/13/14.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Hollow Metal, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339585119.