TAMPA, FL ·
OSHA Inspection: HOLLOW METAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HOLLOW METAL, INC. in 5275 CAUSEWAY BLVD, TAMPA, FL 33619 (NAICS 332321). OSHA activity number 339585119.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOLLOW METAL, INC.
- Site address
- 5275 CAUSEWAY BLVD
- City
- TAMPA
- State
- FL
- ZIP
- 33619
- Mailing
- 5275 CAUSEWAY BLVD, TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 17
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 31, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $1,600 · Current $675 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Throughout Plant The employer did not establish and implement a written energy control program, on or about, 02/13/14.
Recent events (2)
- · I (S) $675
- · Z (S) $1600
1910.212 A01
- Issued
- Mar 31, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $2,000 · Current $825 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by an inadequately guarded power press and unguarded unsed portion of a press brake. a) Door Department - Zeh & Hannemann 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14. b) Spot Welding Area - Niagara 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14. c) Press Brake Department - Cincinnati Press Brakes 250 Tons (2) Unguarded used portions of press dies, on or about, 02/13/14.
Recent events (2)
- · I (S) $825
- · Z (S) $2000
1910.212 A03 II
- Issued
- Mar 31, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $2,000 · Current $825 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Metal Stud Area - Verson All Steel Press Brake - 45 Ton - Serial # 11536-2062-A Unguarded point of operation, on or about, 02/13/14. b) Press Brake Department - Cincinnati Press Brakes (2) 250 Tons - Unguarded point of operations, on or about, 02/13/14. c) Door Department - Lors Machinery Inc. Spot Welder - Model # 140 AR-OV - Serial # 100-6811 - Unguarded point of operation, on or about, 02/13/14. d) Spotwelding Area - Lors Spot Welder - Serial # 1955864 - Model # 418 Unguarded point of operation, on or about, 02/13/14. e) Shear Area - Accurshear Shear - Model# 613510 - Serial # 3401 - Inadequately guarded point of operation and an unguarded point of operation behind the shear, on or about, 02/13/14.
Recent events (2)
- · I (S) $825
- · Z (S) $2000
1910.219 B01
- Issued
- Mar 31, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $1,600 · Current $675 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a) a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press Inadequately guarded flywheel on inside face of machine, on or about, 02/13/14.
Recent events (2)
- · I (S) $675
- · Z (S) $1600
1910.217 B04 II
- Issued
- Mar 31, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(4)(ii): Mechanical power press(es) using full revolution clutches were not provided with a pad with a nonslip contact area firmly attached to the pedal: a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons The foot pedal was missing a non-slip pad, on or about, 02/13/14.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.217 B04 III
- Issued
- Mar 31, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(4)(iii): Pedal return spring(s) of pedal(s) used on mechanical power press(es) using full revolution clutches were not of the compression type, operating on a rod or guided within a hole or tube, or designed to prevent interleaving of sspring coils in the event of breakage: a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons - The pedal spring was not operating on a rod or guided within a hole or tube and was attached to the press's single stroke mechanism via a string, on or about, 02/13/14.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B01
- Issued
- Mar 31, 2014
- Abate by
- Apr 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press The power powering the press's foot pedal was torn from the grommet allowing for exposed live insulated conductors, on or about, 02/13/14.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Hollow Metal, INC.
View Hollow Metal, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339585119.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.