HOUSTON, TX ·
OSHA Inspection: RAM EXTERIOR REMODELING, L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAM EXTERIOR REMODELING, L.L.C. in 2604 MONTROSE, HOUSTON, TX 77006 (NAICS 238990). OSHA activity number 339587800.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAM EXTERIOR REMODELING, L.L.C.
- Site address
- 2604 MONTROSE
- City
- HOUSTON
- State
- TX
- ZIP
- 77006
- Mailing
- 1510 PARK DR., SEABROOK, TX 77586
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 4
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.451 A06
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person: (a) at the Montrose Townhouse Lofts, Apartment 2604, a mason's scaffold was not constructed in accordance with the design.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 C01 II
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1)(ii): 29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces at each end of the scaffold and/or at horizontal intervals not to exceed 30 feet (9.1 m): (a) at Montrose Townhouse Lofts, 2604 Montrose, Houston, TX, only one end of the four section scaffold was braced.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.452 C02
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) at Montrose Townhouse Lofts, 2604 Montrose, Houston, TX, the four section tubular welded frame (masons) scaffold had cross bracing on one side only.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 B01
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) at the Montrose Townhouse Lofts, Apartment 2604, the mason's scaffold that was not fully decked on all working levels.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 E01
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: (a) at the Montrose Townhouse Lofts, Apartment 2604, a ladder was not provided. Employees accessed the working levels by climbing the end frames and cross-braces.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 G04 IV
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface: (a) at the Montrose Townhouse Lofts, Apartment 2604, the mason's scaffold was not equipped with midrails.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1926.451 H01
- Issued
- Mar 7, 2014
- Abate by
- Mar 11, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects: (a) at the Montrose Townhouse Lofts, Apartment 2604, a four section mason's scaffold was not equipped with toeboards.
Recent events (2)
- · I (S) $720
- · Z (S) $1200