Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: RAM EXTERIOR REMODELING, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAM EXTERIOR REMODELING, L.L.C. in 2604 MONTROSE, HOUSTON, TX 77006 (NAICS 238990). OSHA activity number 339587800.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RAM Exterior Remodeling, L.L.C. for free Get an email when a new federal OSHA severe-injury report for RAM Exterior Remodeling, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
2604 MONTROSE
City
HOUSTON
State
TX
ZIP
77006
Mailing
1510 PARK DR., SEABROOK, TX 77586
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
4
Ownership type
Private (A)

7 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person:    (a) at the Montrose Townhouse Lofts, Apartment 2604, a mason's scaffold was not constructed in accordance with the design.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 C01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(1)(ii): 29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces at each end of the scaffold and/or at horizontal intervals not to exceed 30 feet (9.1 m):   (a) at Montrose Townhouse Lofts, 2604 Montrose, Houston, TX, only one end of the four section scaffold was braced.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.452 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  (a) at Montrose Townhouse Lofts, 2604 Montrose, Houston, TX, the four section tubular welded frame (masons) scaffold had cross bracing on one side only.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    (a) at the Montrose Townhouse Lofts, Apartment 2604, the mason's scaffold that was not fully decked on all working levels.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    (a) at the Montrose Townhouse Lofts, Apartment 2604, a ladder was not provided.  Employees accessed the working levels by climbing the end frames and cross-braces.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 G04 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:     (a) at the Montrose Townhouse Lofts, Apartment 2604, the mason's scaffold was not equipped with midrails.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 H01

Serious Gravity 1 2 instances 4 exposed
Issued
Mar 7, 2014
Abate by
Mar 11, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects:    (a) at the Montrose Townhouse Lofts, Apartment 2604, a four section mason's scaffold was not equipped with toeboards.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339587800.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.