Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: ROSEWOOD CABINET COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROSEWOOD CABINET COMPANY, INC. in 1300 HOWARD ST, ELK GROVE VILLAGE, IL 60007 (NAICS 238350). OSHA activity number 339590119.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rosewood Cabinet Company, INC. for free Get an email when a new federal OSHA severe-injury report for Rosewood Cabinet Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1300 HOWARD ST
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
1300 HOWARD ST, ELK GROVE VILLAGE, IL 60007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
12
Ownership type
A

10 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 12, 2014
Abate by
Apr 7, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):       a) Shop Area - The employer did not ensure that each powered industrial truck operator was competent to operate the Hyster electric lift truck safely as demonstrated by the successful completion of training and evaluation.       In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.213 A15

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 12, 2014
Abate by
May 23, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(a)(15): Combs (featherboards) or suitable jigs were not provided at the workplace for use when a standard guard could not be used, as in dadoing, grooving, jointing, moulding, and rabbeting:    a) Shop Area - The Powermatic table saw was not provided with combs (featherboards) or suitable jigs when a standard guard was not used during dadoing, grooving, jointing, and plunge cutting.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a) Shop Area - The Tannewitz table ripsaw was not guarded by automatically adjusting hoods which completely enclosed that portion of the saw above the table and above the material being cut.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:    a) Shop Area - The Tannewitz table ripsaw was not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator.    In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 C03

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 12, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:    a) Shop Area - The Powermatic table saw did not have non kickback fingers or dogs so located to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.    b) Shop Area - The Tannewitz table ripsaw did not have non kickback fingers or dogs so located to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a) Shop Area - The Tannewitz crosscutting table saw was not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 B03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 12, 2014
Abate by
Apr 7, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:       a) Shop Area - Provisions were not made to prevent The Powermatic Table Saw from automatically restarting upon restoration of power after power failure.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1910.213 H03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
Apr 7, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(h)(3): Radial saw(s) were not provided with an adjustable stop to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations:      a) Shop Area - The Delta Rockwell Radial Saw (s/n 2853-B) did not have an adjusted stop to prevent the forward travel of the blade beyond the table.      In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.213 P04

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
Apr 7, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points:      a) Shop Area - The Mattison horizontal belt sander did not have guards at each nip point where the sanding belt ran onto a pully, to prevent the operator's hands or fingers from coming into contact with nip points.       In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1904.29 A

Other-than-serious 1 instance 1 exposed
Issued
Mar 12, 2014
Abate by
Apr 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent.  a) Facility Wide - On February 2, 2014, an employee injured a finger that resulted in lost workdays and the employer did not enter the recordable injury on the OSHA 300 log.   In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Rosewood Cabinet Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339590119.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.