On , OSHA opened a complaint health inspection of SOUTHEAST LINEN ASSOCIATES, INC. in 315 SHAWNEE NORTH DR STE 350, SUWANEE, GA 30024 (NAICS 812331). OSHA activity number 339590713.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southeast Linen Associates, INC. for free Get an email when a new federal OSHA severe-injury report for Southeast Linen Associates, INC. is published. One employer, no account, unsubscribe in one click.
Site address
315 SHAWNEE NORTH DR STE 350
City
SUWANEE
State
GA
ZIP
30024
Mailing
315 SHAWNEE NORTH DR STE 350, SUWANEE, GA 30024
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812331
Employees
95
Ownership type
A

12 citations on file for this inspection.

1910.132 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use PPE.  On or about February 20, 2014 the employer did not provide ppe training to the maintenance employee who is provided safety glasses, face shield, nitrile gloves, and coated gloves to replace 55 gallon drums of corrosive 30-33% hydrogen peroxide at the chemical station adjacent to the sort area.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.303 B02

Serious Gravity 1 1 instance 36 exposed
Issued
Jun 27, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.  a.  On or about April 04, 2014 the employer provided an Underwriters Laboratories listed relocatable power tap connected to a flexible cord and plug rather than directly to a receptacle to supply power to the wrapping table at the number four ironing machine in the Production Area.  b.  On or about April 04, 2014 the employer did not securely fasten in place a four inch square metal receptacle box used to supply power to the cord and plug connected wrapping table at ironer #1.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.  On or about April 04, 2014 in the production area the employer provided a flexible cord and plug which was missing the grounding pin and was connected to an unmounted four inch metal electrical box to supply power to the wrapping table at ironer #1.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 27, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed.  a.  On or about May 06, 2014 two unused openings were not effectively closed in an "Eaton" electrical disconnect box mounted to the wall behind, and supplying power to, the Challenge Tumbler industrial dryer, model CPG4.04.046A, serial number CPG4-3X1L-00793 in the Wash Floor area.  b.  On or about May 06, 2014 an unused opening was not effectively closed in a four inch metal electrical box supplying power to the blower motor of the Challenge Tumbler industrial dryer, model CPG4.04.046A, serial number CPG4-3X1L-00793 in the Wash Floor area.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.305 G01 IV A

Serious Gravity 1 1 instance 36 exposed
Issued
Jun 27, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cord was used as a substitute for the fixed wiring of a structure.  On or about April 04, 2014 the employer had installed flexible cord for fixed wiring of the structure where a length of flexible cord was hard wired into a wall-mounted, four-inch receptacle box in the Production Area and was being used to supply power to the wrapping table adjacent to the number four ironing machine.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.  On or about February 20, 2014, the employer did not include in the written hazard communication program how the requirements for training specified in paragraph (h) will be met.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.1200 E01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(ii): The employer's hazard communication program did not include the methods the employer will use to inform employees of the hazards of non-routine tasks.  On or about February 20, 2014, the employer did not include in the written hazard communication program how the employer will inform employees of the hazards of non-routine tasks.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 95 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Where the employer determined that voluntary respirator use was permissible, the employer did not provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard").  The employer provided "Body Guard Safety Gear" N95 filtering face-piece respirators for voluntary use by employees without also providing those employees with the information contained in Appendix D to 1910.134.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.146 C01

Other-than-serious 1 instance 9 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces are permit-required confined spaces.   On or about February 20, 2014 the employer had not evaluated the workplace to determine if any spaces including, but not limited to, industrial washers and dryers were permit-required confined spaces.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 93 exposed
Issued
Jun 27, 2014
Abate by
Aug 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer did not also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.  On or about February 20, 2014 the employer provided hand-held, portable fire extinguishers throughout the workplace for voluntary use by employees but did not provide the employees with information to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 A02 X

Other-than-serious 1 instance 36 exposed
Issued
Jun 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  On or about April 04, 2014 in the production area the employer provided a flexible cord and plug which had unrepaired damage penetrating the outer jacket at four locations along its length to supply power to the wrapping table at ironer #1.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G01 IV D

Other-than-serious 1 instance 7 exposed
Issued
Jun 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cord was used where attached to building surfaces.   On or about February 20, 2014 the employer connected a "UniMac Company, Inc." UniDryer industrial dryer to a wall mounted receptacle box using a cord and plug attached with cable ties to building surfaces.