Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A1 CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A1 CONSTRUCTION, INC. in 5308 RENO RD., NW, WASHINGTON, DC 20013 (NAICS 236118). OSHA activity number 339591901.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A1 Construction, INC. — free Get an email when a new federal OSHA severe-injury report for A1 Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5308 RENO RD., NW
City
WASHINGTON
State
DC
ZIP
20013
Mailing
5823 KESTRELL CT., BURKE, VA 22015
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 25, 2014
Abate by
Apr 12, 2014
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:     a) Roof - On or about, 02/06/2014, carpenters installing cedar shakes with a pneumatic nail gun were not provided with head protection.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $650
  • — Z (S) $1200

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 25, 2014
Abate by
Apr 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   a)  Roof - On or about, 02/06/2014, carpenters installing cedar shakes with a pneumatic nail gun were not provided with eye protection.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 25, 2014
Abate by
Apr 12, 2014
Penalty
Initial $1,600 · Current $850 Reduced
29 CFR 1926.451(b)(3): Where guardrails were not installed along the front edge of the platform or all employees were not protected from falling with the use of personal fall arrest systems, the front edge of the scaffold platform was more than 14 inches:     a)  SE Corner of House - On or about, 02/06/2014, a carpenter was nailing cedar shakes onto the exterior wall of a house from the platform of a pump jack scaffold whose platform was located (horizontally) 16 in. from the exterior wall.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1600

1926.451 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 25, 2014
Abate by
Apr 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(iv): Each employee on a self-contained adjustable scaffold was not protected by a guardrail system:  a)  SE Corner of House - On or about, 02/06/2014, a carpenter installing cedar shakes from the platform of a pump jack scaffold which was not provided with a midrail.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 25, 2014
Abate by
Apr 12, 2014
Penalty
Initial $1,600 · Current $850 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)  Roof - On or about, 02/06/2014, four carpenters installing cedar shakes and removing debris from a low-sloped roof were not provided with fall protection and exposed to a 11 foot fall.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 25, 2014
Penalty
Initial $1,200 · Current $650 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:     a)  Roof - On or about, 02/06/2014, carpenters installing cedar shakes and removing debris from a low-sloped roof were exposed to a 11 foot fall from an aluminum extension ladder which did not project 3 feet above the ladder landing or that was not secured in place and provided with a grabrail.
Recent events (2)
  • — I (S) $650
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339591901.