Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PAEZ DRYWALL

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of PAEZ DRYWALL in 12240-A MURPHY ROAD PLAZA, MEADOWS PLACE, TX 77477 (NAICS 238190). OSHA activity number 339592180.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paez Drywall for free Get an email when a new federal OSHA severe-injury report for Paez Drywall is published. One employer, no account, unsubscribe in one click.
Establishment
PAEZ DRYWALL
Site address
12240-A MURPHY ROAD PLAZA
City
MEADOWS PLACE
State
TX
ZIP
77477
Mailing
2422 W. LITTLE YORK RD., HOUSTON, TX 77091
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
15
Ownership type
Private (A)

5 citations on file for this inspection.

1926.451 A06

Serious Gravity 10 1 instance 8 exposed
Issued
Apr 21, 2014
Abate by
May 6, 2014
Penalty
Initial $2,520 · Current $1,800 Reduced
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person:         At 12240-a Murphy Road, Stafford, TX; the employer erected used a tubular welded scaffold with deficiencies such as not fully planked between the uprights, missing guardrails, missing means of access and missing mud sills, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2520

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 21, 2014
Abate by
May 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)        At 12240-a Murphy Road, Stafford, TX; employees used a tubular welded scaffold which was not planked/decked between the uprights, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 21, 2014
Abate by
May 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation:      At 12240-a Murphy Road, Stafford, TX; employees used a tubular welded scaffold without mud sills, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 21, 2014
Abate by
May 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:       At 12240-a Murphy Road, Stafford, TX; employees used a tubular welded scaffold without guardrails, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 21, 2014
Abate by
May 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.       At 12240-A Murphy Road, Stafford, TX; employees used crossbraces to access tubular welded scaffold, exposing employees to fall hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339592180.