BATON ROUGE, LA —
OSHA Inspection: AIR COMPRESSOR ENERGY SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR COMPRESSOR ENERGY SYSTEMS, INC. in 10151 S. PERDUE, BATON ROUGE, LA 70814 (NAICS 333912). OSHA activity number 339592321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR COMPRESSOR ENERGY SYSTEMS, INC.
- Site address
- 10151 S. PERDUE
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70814
- Mailing
- 10151 S. PERDUE, BATON ROUGE, LA 70814
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333912
- Employees
- 23
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.179 J01 II A
- Issued
- May 7, 2014
- Abate by
- May 19, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.179(j)(1)(ii)(a): Frequent inspection - Daily to monthly intervals were not performed: On or about February 18, 2014, at 10151 S. Perdue, Baton Rouge, LA, employees were operating two 10 ton overhead cranes to move material in the shop area without frequent inspections.
Recent events (2)
- — I (O) $1000
- — Z (S) $2000
1910.179 J02
- Issued
- May 7, 2014
- Abate by
- May 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: On or about February 18, 2014, at 10151 S. Perdue, Baton Rouge, LA, employees were operating two 10 ton overhead cranes that were not inspected for defects during intervals.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L06
- Issued
- May 7, 2014
- Abate by
- May 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about February 18, 2014, at 10151 S. Perdue, Baton Rouge, LA., employees were operating a forklift to move material at the facility and were not certified by the employer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AIR Compressor Energy Systems, INC.
View AIR Compressor Energy Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333912)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339592321.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.