Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TENARIS COILED TUBES, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of TENARIS COILED TUBES, LLC in 8615 E. SAM HOUSTON PKWY N, HOUSTON, TX 77044 (NAICS 332996). OSHA activity number 339593493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tenaris Coiled Tubes, LLC — free Get an email when a new federal OSHA severe-injury report for Tenaris Coiled Tubes, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8615 E. SAM HOUSTON PKWY N
City
HOUSTON
State
TX
ZIP
77044
Mailing
8615 E. SAM HOUSTON PKWY N, HOUSTON, TX 77044
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
300
Ownership type
A

1 citation on file for this inspection.

1910.212 A03 II

Serious Gravity 5 4 instances 8 exposed
Issued
Feb 26, 2014
Abate by
Mar 17, 2014
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    The employer does not guard the point of operation on all machines whose operation exposes employees to injury.       a. This violation occurred on or about February 20, 2014, in the welding section of payoff line #1 where employees were exposed to a crushed-by hazard when operating welding hold down clamps without a point of operation guard.       b. This violation occurred on or about February 20, 2014, in the welding section of payoff line #2 where employees were exposed to a crushed-by hazard when operating welding hold down clamps without a point of operation guard.         c. This violation occurred on or about February 20, 2014, in the welding section of payoff line #3 where employees were exposed to a crushed-by hazard when operating welding hold down clamps without a point of operation guard.         d. This violation occurred on or about February 20, 2014, in the welding section of payoff line #4 where employees were exposed to a crushed-by hazard when operating welding hold down clamps without a point of operation guard.       Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all the point of operations on all machines are guarded.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000