TOCCOA, GA ·
OSHA Inspection: BRIDGESTONE GCS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRIDGESTONE GCS, LLC in 8989 HWY 17, TOCCOA, GA 30577 (NAICS 238210). OSHA activity number 339594277.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRIDGESTONE GCS, LLC
- Site address
- 8989 HWY 17
- City
- TOCCOA
- State
- GA
- ZIP
- 30577
- Mailing
- 616-B MEDLOCK ROAD, DECATUR, GA 30033
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- May 7, 2014
- Abate by
- Jun 3, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about February 18, 2014: a) Employees were exposed to electrical shock and or burns when the employer installed nonmetallic sheathing cable for temporary power to use within the structure being constructed. The cable being used was laid upon the ground and was not protected.
Recent events (1)
- · Z (S) $1600
1926.405 A02 II A
- Issued
- May 7, 2014
- Abate by
- Jun 3, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(A): Temporary wiring feeder conductors were not run as multiconductor cord or cable assemblies or within raceways; or, where not subject to physical damage, run as open conductors on insulators not more than 10 feet apart: On or about February 18, 2014: a) Employees were exposed to electrical shock and burns when the employer failed to protect nonmetallic sheathed cable that was being used for temporary power on the work site.
Recent events (1)
- · Z (S) $1600
1926.416 A01
- Issued
- May 7, 2014
- Abate by
- Jun 3, 2014
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about February 18, 2014: a) Employers were exposed to electrical shock or burns when the employer failed properly guard the non-metallic sheathed cable that had been spliced and was covered by electrical tape as a form of insulation.
Recent events (1)
- · Z (S) $2400
More inspections in this industry (NAICS 238210)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339594277.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.