OSHA Inspection: US FISH & WILDLIFE SERVICE

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of US FISH & WILDLIFE SERVICE in 1440 ABERNATHY CREEK RD., LONGVIEW, WA 98632 (NAICS 924120). OSHA activity number 339595464.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Fish & Wildlife Service — free Get an email when a new federal OSHA severe-injury report for US Fish & Wildlife Service is published. One employer, no account, unsubscribe in one click.
Site address
1440 ABERNATHY CREEK RD.
City
LONGVIEW
State
WA
ZIP
98632
Mailing
1440 ABERNATHY CREEK RD., LONGVIEW, WA 98632
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
25
Ownership type
D

9 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
May 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  A)     At the Abernathy Fish technology center, did not include all confined spaces at the facility in their workplace evaluation.  An example of confined spaces not evaluated included, but were not limited to the large tanks in the water tower used to add oxygen to the facility water supply.
Recent events (1)
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
May 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  A)    In the extruder room, in the nutrition section, as well as other places throughout the facility, the employer did not have lockout procedures developed to make sure all sources of energy were isolated from the equipment being maintained.  An example of equipment that needed lockout procedures included, but was not limited to the large fixed extruder used to make fish food, in the nutrition section of the facility.
Recent events (1)
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  A)  In the woodworking portion of the miantenance shop, there was a chop saw that did not have guards over half of the blade, exposing employees to the blade.
Recent events (1)
  • — Z (S) $0

1910.305 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
May 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:  A)     In the Wet Lab, electrical outlets and boxes were not wired for for a wet location
Recent events (1)
  • — Z (S) $0

1910.305 E02

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
May 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures:  A)     In the wet lab, electrical switches were not wired for a wet location.
Recent events (1)
  • — Z (S) $0

1910.305 J01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
May 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts:  A)     In the wet lab, several of the light fixtures were not wired fora  wet location.
Recent events (1)
  • — Z (S) $0

1910.25 D01 X

Other-than-serious 1 instance 3 exposed
Issued
Apr 3, 2014
Abate by
Apr 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.25(d)(1)(x): Ladders were not inspected frequently and those which have developed defects were not withdrawn from service for repair or destruction and tagged or marked as "Dangerous, Do Not Use.":  A)  In the Nutrition section of the facility underneath the food extruder, there was a damaged 4 foot high wooden step ladder that was showing signs of damage, that was still being used by employees.
Recent events (1)
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 5 exposed
Issued
Apr 3, 2014
Abate by
Jul 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form:  A)     The employer had a respiratory proteciton program in place, and there were respirators located on site, but they did not have a site specific respirator analysis.
Recent events (1)
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  A)     In the generator room, and adjacent storage room, fluorescent lights were 7 feet 9 inches from the floor and were not protected from damage.
Recent events (1)
  • — Z (O) $0

View US Fish & Wildlife Service's full OSHA safety record →