LYNBROOK, NY ·
OSHA Inspection: AR TECHNICA CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AR TECHNICA CORP. in 443 SUNRISE HWY., LYNBROOK, NY 11563 (NAICS 236220). OSHA activity number 339595944.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AR TECHNICA CORP.
- Site address
- 443 SUNRISE HWY.
- City
- LYNBROOK
- State
- NY
- ZIP
- 11563
- Mailing
- 4802 25TH AVE., SUITE 406, ASTORIA, NY 11103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Mar 6, 2014
- Penalty
- Initial $1,200 · Current $660 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - Employees working directly under ongoing panel installation did not have head protection; on or about 02/20/14. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- · I (S) $660
- · Z (S) $1200
1926.451 B01
- Issued
- Mar 6, 2014
- Abate by
- Mar 12, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, Southeast corner - Employees were installing panels from a fabricated frame scaffold that was not fully planked; on or about 02/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
1926.451 B05 I
- Issued
- Mar 6, 2014
- Abate by
- Mar 12, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. a) worksite, Southeast Corner - An employee was working from a scaffold platform that extended over its support approximately 28 inches ; on or about 02/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
1926.451 E01
- Issued
- Mar 6, 2014
- Abate by
- Mar 12, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Worksite, Southeast corner - Employees installing panels used the crossbraces and scaffold frame to access the platform approximately 11 feet 6 inches above the ground; on or about 02/20/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
1926.451 F06
- Issued
- Mar 6, 2014
- Abate by
- Mar 12, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). a) worksite, Southeast corner - Employees were installing panelling from a fabricated frame scaffold that was approximately 8 inches from an approximate 220 volt insulated electrical line; on or about 02/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
1926.451 G01 VII
- Issued
- Mar 6, 2014
- Abate by
- Mar 12, 2014
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite - Southeast corner - Employees installing panels from a fabricated frame scaffold approximately 11 feet 6 inches above the ground were not protected from falling; on or about 02/20/2014. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1540
- · Z (S) $2800
1926.454 A
- Issued
- Mar 6, 2014
- Abate by
- Mar 25, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) worksite - Employees working from a fabricated frame scaffold were not trained to recognize hazards and correct the hazards; on or about 02/20/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $1100
- · Z (S) $2000
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339595944.