OSHA Inspection: DAG CUSTOM HOMES

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DAG CUSTOM HOMES in 2601 BELFORD, GRAND JUNCTION, CO 81501 (NAICS 238170). OSHA activity number 339596314.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DAG Custom Homes for free Get an email when a new federal OSHA severe-injury report for DAG Custom Homes is published. One employer, no account, unsubscribe in one click.
Establishment
DAG CUSTOM HOMES
Site address
2601 BELFORD
City
GRAND JUNCTION
State
CO
ZIP
81501
Mailing
2518 MONUMENT ROAD, GRAND JUNCTION, CO 81507
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 27, 2014
Abate by
Mar 14, 2014
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section:      (a)       DAG Custom Homes, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, as the controlling contractor onsite, DAG Custom Homes did not ensure that the supported scaffold was designed by a qualified person, in that the scaffold wood platform was constructed at the job site by non qualified personnel. A skid steer was used to elevate an employee approximately 15 feet on a job made scaffold in order to perform siding work. This condition exposed the employee to a fall hazard of approximately 15 feet.      Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2014
Abate by
Mar 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1):  Each employee on a scaffold 10 feet above a lower level was not protected from falling to the lower level:       (a)        DAG Custom Homes, 2601 Belford Ave., Grand Junction, CO 81501:  On and before January 28, 2014, as the controlling contractor onsite, DAG Custome Homes did not ensure that employees were protected from a fall from elevation, in that guardrails or other suitable fall protection were not properly installed on the working platform of the scaffolding. This condition exposed employees to a fall of approximate 15 feet.    Abatement Note:  Abatement certification is required for this item (see enclosed Abatement-Certification Letter").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.20 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 27, 2014
Abate by
Mar 14, 2014
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying hazards associated with aerial lifts).       (a)   DAG Custom Homes, 2601 Belford Ave., Grand Junction, CO 81501: On and before January 28, 2014, the controlling employer did not ensure that a competent person was onsite and evaluating the hazards associated with siding operations.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

View DAG Custom Homes's full OSHA safety record →