SAN ANTONIO, TX —
OSHA Inspection: U.S. PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. PRODUCTS in 1315 N. OLIVE ST., SAN ANTONIO, TX 78202 (NAICS 332312). OSHA activity number 339597239.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. PRODUCTS
- Site address
- 1315 N. OLIVE ST.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78202
- Mailing
- 1315 N. OLIVE ST., SAN ANTONIO, TX 78202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.219 D01
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Main Building, compressor area, Speedaire compressor: On or about January 23, 2014, employees were exposed to a caught-in hazard, due to a missing guard, used to cover the pulley/power transmission of the compressor.
Recent events (1)
- — Z (S) $1600
1910.219 E01
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) Main Building, compressor area, Speedaire compressor: On or about January 23, 2014, employees were exposed to a caught-in hazard, due to a missing guard, used to cover the belt/power transmission of the compressor.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Main Building, mechanism rebuild area, blow-off tool, DG-10: On or about January 23, 2014, employees were exposed to an struck-by hazard, due to a blow-off tool being operated at approximately 120 p.s.i.
Recent events (1)
- — Z (S) $1200
1910.303 B01
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Main Building, Welding area, Millermatic 250 welder: On or about January 23, 2014, employees were exposed to an 240 volt electrocution hazard, due to the welder having poor strain relief, exposing the internal wiring of the cord, near the plug.
Recent events (1)
- — Z (S) $1600
1910.303 G02 I
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) Main Building, near compressor, feeder panel: On or about January 23, 2014, employees were exposed to an electrocution hazard, due to a 120/240 volt feeder panel missing a circuit breaker, exposing employees to the live internal parts of the feeder panel.
Recent events (1)
- — Z (S) $1600
1910.305 B01
- Issued
- Apr 3, 2014
- Abate by
- Apr 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Main Building, grinding area, metal outlet box: On or about January 23, 2014, employees were exposed to an electrocution hazard, due to a 120 volt metal outlet box missing 1/2 inch knock outs, exposing employees to the outlet box internal live wiring.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Products
View U.S. Products's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339597239.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.