PEPPERELL, MA —
OSHA Inspection: KEYSTONE PRECISION AND ENGINEERING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KEYSTONE PRECISION AND ENGINEERING, INC. in 16 LOMAR PARK, SUITE 3, PEPPERELL, MA 01463 (NAICS 332710). OSHA activity number 339599045.
Where did this inspection happen?
- Establishment
- KEYSTONE PRECISION AND ENGINEERING, INC.
- Site address
- 16 LOMAR PARK, SUITE 3
- City
- PEPPERELL
- State
- MA
- ZIP
- 01463
- Mailing
- 16 LOMAR PARK, SUITE 3, PEPPERELL, MA 01463
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.36 G04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $925.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the minimum width requirements for exit routes. (a) Location - Production On or about 2/25/14, the employer failed to maintain the minimum width requirement for an exit route at all points, an object projected into the exit route. There were two milling machines were projecting into aisle in the production area that were less 19 inches from apart restricting the exit route.
Recent events (2)
- — I (S) $925
- — Z (S) $1600
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1525.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Location - Production Area: On or about 2/25/14, the employer failed to establish an adequate energy control program that included procedures for cleaning a CNC vertical milling machine.
Recent events (2)
- — I (S) $1525
- — Z (S) $2800
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1525.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Location - Production: On or about 2/25/14, employees were exposed to amputation hazards when the employer failed to properly guard Fadal CNC Vertical Machining Center. (b) Location - Production: On or about 2/25/14, employees were exposed to amputation hazards when the employer failed to properly guard a Rockwell vertical ban saw. (c) Location - Production: On or about 2/25/14, employees were exposed to amputation hazards when the employer failed to properly guard a HARDINGE COBRA CNC Lathe. (d) Location - Production: On or about 2/25/14, employees were exposed to amputation hazards when the employer failed to properly guard a Haas CNC Lathe.
Recent events (2)
- — I (S) $1525
- — Z (S) $2800
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Location - Production: On or about 2/25/14, employees were cleaning with compressed air and the pressure was not reduced below 30 P.S. I. Employees were cleaning debris from CNC machines.
Recent events (2)
- — I (O) $500
- — Z (S) $2000
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $725.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Location - Production On or about 2/25/14, employees were exposed to electrical shock when the employer failed to ensure that electrical outlets were installed in accordance with instructions included in the listing or labeling.
Recent events (2)
- — I (S) $725
- — Z (S) $1200
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339599045.