OSHA Inspection: NAIAD DYNAMICS US, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAIAD DYNAMICS US, INC. in 50 PARROTT DRIVE, SHELTON, CT 06484 (NAICS 336999). OSHA activity number 339599599.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naiad Dynamics US, INC. for free Get an email when a new federal OSHA severe-injury report for Naiad Dynamics US, INC. is published. One employer, no account, unsubscribe in one click.
Site address
50 PARROTT DRIVE
City
SHELTON
State
CT
ZIP
06484
Mailing
50 PARROTT DRIVE, SHELTON, CT 06484
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336999
Employees
44
Ownership type
Private (A)

9 citations on file for this inspection.

1910.132 E

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 24, 2014
Penalty
Initial $2,100 · Current $1,200 Reduced
29 CFR 1910.132(e): Defective and damaged equipment. Defective or damaged personal protective equipment shall not be used.    WORKSHOP:  The right glove of the Cyclone sandblaser was defective and ripped.      ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2100

1910.213 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 24, 2014
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.213(b)(3): On applications where injury to the operator might result if motors were to restart after power failures, provision shall be made to prevent machines from automatically restarting upon restoration of power.    WORKSHOP:  The Craftsman table saw was not equipped with a magnetic starter.      ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1910.219 C02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 24, 2014
Penalty
Initial $3,500 · Current $2,400 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    WORKSHOP:  The horizontal shafts of the following equipment were unguarded:      1.    The horizontal shaft/cutter of the Milwaukee Simplex milling machine.      2.    The horizontal shafts of the Admiral buffer/wire brusher.          ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $2400
  • · Z (S) $3500

1910.219 C04 I

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.  WORKSHOP:  The horizontal shaft ends/nuts of the following equipment were unguarded:                       1.   The horizontal shaft end/nut of the Milwaukee Simplex milling machine.     2.   The horizontal shaft ends/nuts of the Admiral buffer/wire brusher.     ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 I

Other-than-serious 1 instance 2 exposed
Issued
Mar 24, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.305(g)(1)(i): Flexible cords and cables shall be approved for conditions of use and location.    WORKSHOP:  The flexible cord of the Craftsman table saw was exposed to potential physical damage due to the presence of pieces of wood in front of the electrical outlet into which the attachment plug of the saw was pluged.        ABATED DURING THE INSPECTION
Recent events (2)
  • · I (O) $0
  • · Z (S) $2800

1910.307 C

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Mar 24, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.307(c): Electrical installations. Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location.   WORKSHOP:  The electrical equipment, such as (but not limited to) outlets and other equipment installed on woodworking machineries and in the area where combustible wood dust was generated and accumulated were neither approved nor intrinsically safe for the Class II Division 2 hazardous location.    ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 24, 2014
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.     WORKSHOP: The employer had not established and implemented a written hazard communication program where employees were required to work with chemicals, such as (but not limited to) the coolants and degreaser.       ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.   WORKSHOP:  The employees were not all provided with appropriate training and information on the safety data sheets and labeling information who were required to work with chemicals, such as (but not limited to) coolant and degreaser.   ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.132 D02

Other-than-serious 1 instance 5 exposed
Issued
Mar 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  WORKSHOP:  The employer had not verified through a written certification that the workplace hazard assessment for personal protective equipment (PPE) had been performed as complete.    ABATED DURING THE INSPECTION.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Naiad Dynamics US, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339599599.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.