Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: ALL PHASE STEEL WORKS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ALL PHASE STEEL WORKS, LLC in 480 BUNNELL STREET, BRIDGEPORT, CT 06607 (NAICS 332323). OSHA activity number 339599771.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Phase Steel Works, LLC for free Get an email when a new federal OSHA severe-injury report for ALL Phase Steel Works, LLC is published. One employer, no account, unsubscribe in one click.
Site address
480 BUNNELL STREET
City
BRIDGEPORT
State
CT
ZIP
06607
Mailing
480 BUNNELL STREET, BRIDGEPORT, CT 06607
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
25
Ownership type
A

13 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 3 exposed
Issued
May 21, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    ESTABLISHMENT:  The emergency exit door was obstructed by a table and a steel ornament.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.132 D02

Serious Gravity 5 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 17, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:    ESTABLISHMENT:  The employer did not verify through written certification, the Workplace Hazard Assessment plan.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.135 A01

Serious Gravity 1 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:  ESTABLISHMENT:  The employees operating an overhead crane to hoist steel and equipment were not provided with protective hard hats.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 P01

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2014
Abate by
Jun 17, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    ESTABLISHMENT:  The Mitsubishi forklift truck used by the forklift operator with a broken front light and severely torn seat  and had not been removed from service until repaired.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
May 21, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:    ESTABLISHMENT:  A compressed gas cylinder of oxygen was stored on a cart with a compressed gas cylinder of acetylene.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.254 D09 III

Serious Gravity 5 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 3, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:    ESTABLISHMENT:  The insulation of the cables used for the Airco "Tig" Heliwelder were damaged and had exposed bare conductors.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    ESTABLISHMENT:  The electrical metal outlet box used to power a Hobart welding machine was not securely mounted as required and was subject to physical damage.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.305 B01

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:  ESTABLISHMENT:  The electrical metal outlet box used to power a Hobart welding machine had an unused opening.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 2 exposed
Issued
May 21, 2014
Abate by
Jun 3, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    ESTABLISHMENT:  The attachment plug of the orange/black flexible cord used to power a P&H welder machine was missing a grounding pin.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 3, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:Note:  Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.    ESTABLISHMENT:  The orange/black flexible cord used to power a P&H welder machine was repaired by splicing which did not retain the insulation, outer sheath properties, and usage characteristics of the cord.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2014
Abate by
Jun 3, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    ESTABLISHMENT:  The outer insulation was pulled away exposing the insulated conductors at both the attachment point to Enco Band saw and at the attachment to the plug.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1904.32 B03

Other-than-serious 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 17, 2014
Penalty
Initial $1,000 · Current $500 Reduced
29 CFR 1904.32(b)(3): The Summary of Work Related Injuries and Illnesses (OSHA Form 300A or equivalent) was not properly certified:    ESTABLISHMENT:  The OSHA 300A Summary form for 2013 was not signed and certified by a company executive.
Recent events (2)
  • · I (O) $500
  • · Z (O) $1000

1910.101 B

Other-than-serious 1 instance 3 exposed
Issued
May 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  ESTABLISHMENT:  An Argon compressed gas cylinder in storage was not equipped with a valve cap.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View ALL Phase Steel Works, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339599771.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.