ELMSFORD, NY —
OSHA Inspection: C & F STEEL CORP.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of C & F STEEL CORP. in 14 NO. PAYNE STREET, ELMSFORD, NY 10523 (NAICS 238120). OSHA activity number 339601064.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C & F STEEL CORP.
- Site address
- 14 NO. PAYNE STREET
- City
- ELMSFORD
- State
- NY
- ZIP
- 10523
- Mailing
- 14 NO. PAYNE STREET, ELMSFORD, NY 10523
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.106 E06 II
- Issued
- Apr 15, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected. Location: Painting Area a) Employees transfer xylene from a 55- gallon drum into a 5- gallon plastic container without the nozzle and container being electricallly interconnected; on or about 2/25/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.134 C01
- Issued
- Apr 15, 2014
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Location: Frabrication area a) Employees are required to wear a 3M half-face negative pressure respirator when painting. The employer did not have a written respiratory protection program; on or about 2/25/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
1910.252 B02 III
- Issued
- Apr 15, 2014
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Location: Welding area a) The welding area was not protected by noncombustible or flameproof screens; on or about 2/25/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1910.132 D01
- Issued
- Apr 15, 2014
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment: Location: Workplace a) Employees are engaged in steel fabrication. The employer did not conduct a hazard assessment to determine what type of personal protective equipment is necessary to protect employees; on or about 2/25/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1910.252 B03
- Issued
- Apr 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(b)(3): Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 29 CFR 1910.132: Location: Production area a) Employees performing welding were not provided protective clothing to protect their bodies and extremities from burns; on or about 2/25/14
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Apr 15, 2014
- Abate by
- May 18, 2014
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Location: Workplace a) Employees work with hazardous chemicals such as but not limited to xylene, petroleum solvents and welding fumes. The employer did not develop or implement a written hazard communication program; on or about 2/25/14.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1910.1200 H01
- Issued
- Apr 15, 2014
- Abate by
- May 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Location: Workplace a) Employees work with hazardous chemicals such as but not limited to xylene, petroleum solvents and welding fumes. The employer did not provide hazard communication training; on or about 2/25/14
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at C & F Steel Corp.
View C & F Steel Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339601064.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.