Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: RANDY HAY CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RANDY HAY CONSTRUCTION in BEREAN BIBLE CHURCH, 109 GENEGANSLET ROAD, GREENE, NY 13778 (NAICS 236220). OSHA activity number 339601486.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Randy HAY Construction for free Get an email when a new federal OSHA severe-injury report for Randy HAY Construction is published. One employer, no account, unsubscribe in one click.
Site address
BEREAN BIBLE CHURCH, 109 GENEGANSLET ROAD
City
GREENE
State
NY
ZIP
13778
Mailing
163 ALEXANDER ROAD, CHENANGO FORKS, NY 13746
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
Private (A)

5 citations on file for this inspection.

1926.153 O

Other-than-serious 2 instances 4 exposed
Issued
Mar 3, 2014
Abate by
Mar 11, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken:       a) West side building, south of job trailer, on or about 2-25-14:  Employees were working in an area immediately adjacent to two 100 pound Liquefied Petroleum Gas (LPG) tanks that were not protected against accidental contact.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1600

1926.350 A09

Other-than-serious 2 instances 4 exposed
Issued
Mar 3, 2014
Abate by
Mar 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position:       a) West side building, south of job trailer, on or about 2-25-14:  Employees were working in an area immediately adjacent to two 100 pound Liquefied Petroleum Gas (LPG) tanks that were not secured.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1926.304 F

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Mar 3, 2014
Abate by
Mar 11, 2014
Penalty
Initial $1,600 · Current $0 Reduced
1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:     1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:     1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:    a) North end of building, west of sanctuary, on or about 2-25-14:  Employees were ripping wood and foam panels on a table saw that was not equipped with a spreader.     b) North end of building, west of sanctuary, on or about 2-25-14:  Employees were ripping wood and foam panels on a table saw that was not equipped with non kick-back fingers or "dogs".     c) North end of building, west of sanctuary, on or about 2-25-14:  Employees were ripping wood and foam panels on a table saw that was not equipped with a magnetic switch or anti-restart device.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1926.304 I01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Mar 3, 2014
Abate by
Mar 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut.     a) North end of building, west of sanctuary, on or about 2-25-14:  Employees were ripping wood and foam panels on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 F06

Other-than-serious 2 instances 4 exposed
Issued
Mar 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:       a) West end of building, temporary power panel, on or about 2-25-14:  Employees were operating a variety of hand held power tools and providing power to a trailer, through two cords that did not have a continuous path to ground due to a missing a ground pin.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339601486.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.