Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LD PLASTICS INCORPORATED

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of LD PLASTICS INCORPORATED in 1130 PEARL STREET, BROCKTON, MA 02301 (NAICS 326199). OSHA activity number 339601916.

Watch LD Plastics Incorporated — free Get an email when a new federal OSHA severe-injury report for LD Plastics Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1130 PEARL STREET
City
BROCKTON
State
MA
ZIP
02301
Mailing
1130 PEARL STREET, BROCKTON, MA 02301
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Cutting Room:  1)           The chuck of the Clausing Lather was  not guarded.  2)            The chuck key of the Clausing Lathe was not equipped with a spring to prevent the chuck key from being left in the chuck.   3)            The blade of the Oliver saw used to cut sheets of plastic was not guarded.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1120.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Cutting Room:  1)        The back side of the pulley and belt drive of the panel saw was not guarded.  2)         The pulley and belt drive of the United Band Saw was not enclosed by a guard.  Model Room:              The pulley and belt drive of the bandsaw was not adequately guarded.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339601916.