SAINT LOUIS, MO ·
OSHA Inspection: PAULO PRODUCTS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAULO PRODUCTS COMPANY in 5711 WEST PARK AVENUE, SAINT LOUIS, MO 63110 (NAICS 332811). OSHA activity number 339603011.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAULO PRODUCTS COMPANY
- Site address
- 5711 WEST PARK AVENUE
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63110
- Mailing
- 5620 WEST PARK AVENUE, SAINT LOUIS, MO 63110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332811
- Employees
- 141
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jun 16, 2014
- Abate by
- Aug 1, 2014
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): Location: 5711 West Park Avenue, St. Louis, MO 63110 The employers equipment energy control procedures did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy and did not include specific requirements for the testing of equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures for the following, but not limited to, equipment: a) IPSEN Vacuum Furnace, Equipment #1207, b) G.M. Vacuum Furnace, Equipment #1209, c) Lindberg Rotary Hearth Furnace, Equipment #1601 d) AFC Integral Quench Batch Furnace, Equipment #906
Recent events (2)
- · I (S) $0
- · Z (S) $4250
1910.333 B02 I
- Issued
- Jun 16, 2014
- Abate by
- Aug 1, 2014
- Penalty
- Initial $0 · Current $2,975
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: Location: 5711 West Park Avenue, St. Louis, MO 63110 A written procedure was not available specifying the requirement to test for the absence of voltage after locking out electrical equipment and before performing service on that electrical equipment.
Recent events (2)
- · I (S) $2975
- · Z (S) $0
1910.212 A01
- Issued
- Jun 16, 2014
- Abate by
- Aug 1, 2014
- Penalty
- Initial $3,400 · Current $2,380 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Location: 5711 West Park Avenue, St. Louis, MO 63110 Employees were exposed to the hazard of becoming caught in the rotating chuck while operating the unguarded Clausing drill press, m/n 2277, s/n 510563.
Recent events (2)
- · I (S) $2380
- · Z (S) $3400
More inspections at Paulo Products Company
View Paulo Products Company's full OSHA safety record →
More inspections in this industry (NAICS 332811)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339603011.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.