OSHA Inspection: NARDELLI ELECTRIC, INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of NARDELLI ELECTRIC, INC. in 10515 B HARRISON AVE, HARRISON, OH 45030 (NAICS 238210). OSHA activity number 339603482.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nardelli Electric, INC. for free Get an email when a new federal OSHA severe-injury report for Nardelli Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10515 B HARRISON AVE
City
HARRISON
State
OH
ZIP
45030
Mailing
4240 PICTUREVIEW, CINCINNATI, OH 45247
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 10 2 instances 1 exposed
Issued
Mar 18, 2014
Abate by
Mar 24, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.   Located along the rear interior area of the commercial structure adjacent to a stairway observed in use there is an energized Square D breaker panel board #NF442L6C without the dead front trim panel cover installed exposing live electrical parts therein operating at 110v or greater.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1926.405 G02 IV

Serious Gravity 10 2 instances 1 exposed
Issued
Mar 18, 2014
Abate by
Mar 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.   Located along the rear interior area of the commercial structure there is a 480v SAES #780 Pro Floor Grinder and GE transformer #918368872 observed in use energized powered connected to electrical service panel by black flex cord to a Square D panel board # NF442L6C with the dead front trim panel not in place and transformer conductors to energized panel device without a strain relief coupler/clamp on the flex cord to prevent direct transmission pull to conductor joints at the panel.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339603482.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.