Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BS & B SAFETY SYSTEM, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BS & B SAFETY SYSTEM, LLC in 7455 EAST 46TH ST., TULSA, OK 74145 (NAICS 332999). OSHA activity number 339603953.

Watch BS & B Safety System, LLC — free Get an email when a new federal OSHA severe-injury report for BS & B Safety System, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7455 EAST 46TH ST.
City
TULSA
State
OK
ZIP
74145
Mailing
7455 EAST 46TH ST., TULSA, OK 74145
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
120
Ownership type
A

7 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.106(d)(2)(i): Approved container(s) or portable tank(s) were not used for the storage of flammable or combustible liquids:     On or about February 26, 2014, and at times prior thereto, in the welding areas non approved containers without a self-closing lid were observed being used inside the building to handle and store Class I flammable liquids exposing employees to fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.106 E06 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected.     On or about February 26, 2014, and at times prior thereto, in the flammable liquids storage areas Class I flammable liquids were dispensed into a smaller container without being effectively grounded and bonded to electrically interconnect the containers to prevent static discharge during dispensing operation. Employees were exposed to fire hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:     On or about February 26, 2014, and at times prior thereto, at the micro finish area employees may be exposed to sulfuric acid, an eye wash capable of providing 15 minutes of flushing was not in working condition. Employees were exposed eye injury hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.217 C01 I

Serious Gravity 5 3 instances 4 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $2295.00 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):    On or about February 26, 2014, and at times prior thereto, in the CEP and Sta-Kul areas employees were operating mechanical power presses where the "point of operations" were not effectively guarded. Employees were exposed to an amputation caused by the presses while in operation.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.219 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $2295.00 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    On or about February 26, 2014, and at times prior thereto, in the punch press area employees were exposed to sprocket wheel and chain systems approximately 5-ft. from the floor without a guard provided to prevent employees contacting the sprocket wheels and chains while in operation. Employees were exposed to an amputation and caught in hazards.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.303 B02

Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about February 26, 2014, and at times prior thereto, at the establishment electrical equipment was observed being used not in accordance with the listing instructions, including but not limited to the following instances:     1) In the small disc area a four-plex electrical receptacle was observed being used where it was laid on the floor and not mounted to a wall or structure.     2) In the punch press area a relocatable power tap (RPT) was observed being used to supply power to large current consumption equipment.     Employees were exposed to electric shock and electrical fire hazards.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.304 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:    On or about February 26, 2014, or at times prior thereto, at the punch press area electrical equipment was observed plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339603953.