SOUTH ABINGTON TOWNSHIP, PA —
OSHA Inspection: CREATIVE DESIGN & MACHINING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CREATIVE DESIGN & MACHINING INC. in 969 GRIFFIN POND RD., SOUTH ABINGTON TOWNSHIP, PA 18411 (NAICS 332710). OSHA activity number 339604399.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CREATIVE DESIGN & MACHINING INC.
- Site address
- 969 GRIFFIN POND RD.
- City
- SOUTH ABINGTON TOWNSHIP
- State
- PA
- ZIP
- 18411
- Mailing
- 969 GRIFFIN POND RD., SOUTH ABINGTON TOWNSHIP, PA 18411
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.215 B09
- Issued
- Mar 18, 2014
- Abate by
- May 2, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Machining Area: The distance between the abrasive wheel peripheries and the adjustable tongue guards on the Craftsman bench grinder exceeded one fourth inch, as observed on or about February 28, 2014. Abatement Certification Required
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.253 B04 III
- Issued
- Mar 18, 2014
- Abate by
- May 2, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a) Shipping area: Oxygen and acetylene gas cylinders were in storage together, as observed on or about February 28, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.147 C06 I
- Issued
- Mar 18, 2014
- Abate by
- May 2, 2014
- Penalty
- Initial $1,360 · Current $1,020 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Maintenance: The employer did not conduct a periodic inspection of the energy control procedure at least annually, on or about February 28, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $1020
- — Z (S) $1360
1910.147 C07 I
- Issued
- Mar 18, 2014
- Abate by
- May 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Maintenance: The employer did not provide adequate training to ensure that employees acquired the knowledge and skill required for the safe application, usage and removal of energy control devices to equipment including, but not limited to, CNC operated milling machines and lathes, on or about February 28, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Mar 18, 2014
- Abate by
- May 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Welding area: An electrical handy box was being used as part of an extension cord assembly, as observed on or about February 28, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Creative Design & Machining INC.
View Creative Design & Machining INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339604399.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.