Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VERSA TECHNOLOGIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VERSA TECHNOLOGIES, INC. in 5877 S. PENNSYLVANIA AVE., CUDAHY, WI 53110 (NAICS 333995). OSHA activity number 339605123.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Versa Technologies, INC. for free Get an email when a new federal OSHA severe-injury report for Versa Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5877 S. PENNSYLVANIA AVE.
City
CUDAHY
State
WI
ZIP
53110
Mailing
5877 S. PENNSYLVANIA AVE., CUDAHY, WI 53110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333995
Employees
109
Ownership type
Private (A)

3 citations on file for this inspection.

1910.179 L03 III D

Serious Gravity 5 1 instance 1 exposed
Issued
May 28, 2014
Abate by
Jun 16, 2014
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible:  (a) The pendant control station for the over head crane at the paint booth was not kept clean of paint obscuring the buttons' labeling.
Recent events (2)
  • · I (S) $2520
  • · Z (S) $3600

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
May 28, 2014
Abate by
Jun 16, 2014
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Strain relief was defective on the cord connection of the electrical heater element of the 'driQuik' infrared oven located near the paint booth.  This condition compromises the integrity of the electrical cord sheathing and exposes employees to possible fire or shock.
Recent events (2)
  • · I (S) $1890
  • · Z (S) $2700

1910.1200 F05

Other-than-serious 1 instance 1 exposed
Issued
May 28, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:  (a)  A spray bottle was not tagged with the appropriate identification and warning of hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339605123.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.