COLORADO SPRINGS, CO ·
OSHA Inspection: BOB PENKHUS MAZDA AT POWERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOB PENKHUS MAZDA AT POWERS, INC. in 7455 TEST DRIVE, COLORADO SPRINGS, CO 80923 (NAICS 423110). OSHA activity number 339605545.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOB PENKHUS MAZDA AT POWERS, INC.
- Site address
- 7455 TEST DRIVE
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80923
- Mailing
- 7455 TEST DRIVE, COLORADO SPRINGS, CO 80923
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423110
- Employees
- 30
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.253 A03
- Issued
- Mar 25, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved: a) On or about February 28, 2014 and at times prior, employees were exposed to serious injuries from using an oxygen-acetylene welding equipment. The valve regulator gauge glass cover was missing on both oxygen and the acetylene cylinder.
Recent events (2)
- · I (S) $1750
- · Z (S) $3500
1910.305 J01 I
- Issued
- Mar 25, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles had live parts normally exposed to employee contact: a) On or about February 28, 2014 and at times prior, employees were exposed to electric shock from an energized electrical outlet. The employees used the electrical outlet in the car wash area that was not provided with an outlet cover.
Recent events (2)
- · I (S) $1050
- · Z (S) $2100
1910.305 J02 V
- Issued
- Mar 25, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed): a) On or about February 28, 2014 and at times prior, employees were exposed to electric shock from an energized electrical outlet. The employees used the electrical outlet in the car wash area that was not provided with a weatherproof cover.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 F05 I
- Issued
- Mar 25, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about February 28, 2014 and at times prior, employees were exposed to serious injuries while using several chemicals contained inside the spray containers. The containers were not labeled, tagged, or marked with the identity of the chemicals contained inside.
Recent events (2)
- · I (S) $1050
- · Z (S) $2100
1910.1200 F05 II
- Issued
- Mar 25, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) On or about February 28, 2014 and at times prior, employees were exposed to serious injuries while using several chemicals contained inside the spray containers. The containers were not labeled, tagged, or marked with the appropriate hazard warnings of the chemicals contained inside.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 423110)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339605545.