Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED DRILLING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UNITED DRILLING INC. in RIG #22, PECOS VALLEY STATE LEASE, WELL #1, IMPERIAL, TX 79743 (NAICS 213111). OSHA activity number 339606642.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Drilling INC. — free Get an email when a new federal OSHA severe-injury report for United Drilling INC. is published. One employer, no account, unsubscribe in one click.
Site address
RIG #22, PECOS VALLEY STATE LEASE, WELL #1
City
IMPERIAL
State
TX
ZIP
79743
Mailing
P.O. BOX 2488, ROSWELL, NM 88202
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
14
Ownership type
A

6 citations on file for this inspection.

1910.23 A08

Serious Gravity 1 1 instance 14 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:    On or about February 25, 2014, Rig #22, at the Discharge pit, a floor hole measuring approximately 10-inches by 8-inches was left unguarded. Employees were exposed to trip hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1910.23 C01

Serious Gravity 5 1 instance 14 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $3,600 · Current $2,250 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:    On or about February 25, 2014, Rig #22, the stairway leading up to the discharge pit had unprotected gaps on each side. The unprotected gap on the left side was approximately 2-feet wide and the unprotected gap on the right side was 5-feet 5-inches wide. Employees were exposed to a fall hazard of greater than 4-feet.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3600

1910.27 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.27(b)(1)(ii): The distance between rungs exceeded 12 inches and were not uniform throughout the ladder:      On or about February 25, 2014, on the rig floor of Rig # 22, the ladder leading up to the monkey board was cut 41-inches above the floor and in other areas to accommodate the water valves. This caused the distance between rungs to exceed 12 inches in several areas.  Employees were exposed to the fall hazards greater than 4-feet.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1910.27 B01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.27(b)(1)(iv): Rungs, cleats, and/or steps of fixed ladders were not free of splinters, sharp edges, burrs, or projections that posed a hazard:    On or about February 25, 2014, on the rig floor of Rig # 22, the ladder leading up to the monkey board was obstructed by the water valves. Employees were forced to step on the valves in order to access the ladder. This exposed employees to the fall hazards greater than 4-feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 IV

Serious Gravity 5 1 instance 14 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $3,600 · Current $2,250 Reduced
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation:    On or about February 25, 2014, Rig # 22, coming out of the generator house; the 100-foot 240V nominal electrical cable supplying power to the Top Doghouse had outer insulation damage. Employees were exposed to electrical shock.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3600

1910.305 G01 IV B

Other-than-serious 12 instances 14 exposed
Issued
Apr 23, 2014
Abate by
May 30, 2014
Penalty
Initial $900 · Current $500 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:    On or about February 25, 2014, Rig #22, 110/120V and 220V nominal electrical cables were run through holes in walls. Employees were exposed to electrical shock hazards in the following instances:          1)    Six 120V electrical cables were run through the metal walls of the Generator House.      2)    Two 110V & two 220V electrical cables were through walls of the Top Doghouse.      3)    Two 110V cables were run through the metal roof brackets of the Bottom Doghouse.
Recent events (2)
  • — I (O) $500
  • — Z (O) $900

View United Drilling INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339606642.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.