IMPERIAL, TX —
OSHA Inspection: UNITED DRILLING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNITED DRILLING INC. in RIG #22, PECOS VALLEY STATE LEASE, WELL #1, IMPERIAL, TX 79743 (NAICS 213111). OSHA activity number 339606642.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED DRILLING INC.
- Site address
- RIG #22, PECOS VALLEY STATE LEASE, WELL #1
- City
- IMPERIAL
- State
- TX
- ZIP
- 79743
- Mailing
- P.O. BOX 2488, ROSWELL, NM 88202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 14
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 A08
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $2,700 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: On or about February 25, 2014, Rig #22, at the Discharge pit, a floor hole measuring approximately 10-inches by 8-inches was left unguarded. Employees were exposed to trip hazards.
Recent events (2)
- — I (S) $1500
- — Z (S) $2700
1910.23 C01
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $3,600 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: On or about February 25, 2014, Rig #22, the stairway leading up to the discharge pit had unprotected gaps on each side. The unprotected gap on the left side was approximately 2-feet wide and the unprotected gap on the right side was 5-feet 5-inches wide. Employees were exposed to a fall hazard of greater than 4-feet.
Recent events (2)
- — I (S) $2250
- — Z (S) $3600
1910.27 B01 II
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $2,700 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.27(b)(1)(ii): The distance between rungs exceeded 12 inches and were not uniform throughout the ladder: On or about February 25, 2014, on the rig floor of Rig # 22, the ladder leading up to the monkey board was cut 41-inches above the floor and in other areas to accommodate the water valves. This caused the distance between rungs to exceed 12 inches in several areas. Employees were exposed to the fall hazards greater than 4-feet.
Recent events (2)
- — I (S) $1500
- — Z (S) $2700
1910.27 B01 IV
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(b)(1)(iv): Rungs, cleats, and/or steps of fixed ladders were not free of splinters, sharp edges, burrs, or projections that posed a hazard: On or about February 25, 2014, on the rig floor of Rig # 22, the ladder leading up to the monkey board was obstructed by the water valves. Employees were forced to step on the valves in order to access the ladder. This exposed employees to the fall hazards greater than 4-feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 IV
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $3,600 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation: On or about February 25, 2014, Rig # 22, coming out of the generator house; the 100-foot 240V nominal electrical cable supplying power to the Top Doghouse had outer insulation damage. Employees were exposed to electrical shock.
Recent events (2)
- — I (S) $2250
- — Z (S) $3600
1910.305 G01 IV B
- Issued
- Apr 23, 2014
- Abate by
- May 30, 2014
- Penalty
- Initial $900 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: On or about February 25, 2014, Rig #22, 110/120V and 220V nominal electrical cables were run through holes in walls. Employees were exposed to electrical shock hazards in the following instances: 1) Six 120V electrical cables were run through the metal walls of the Generator House. 2) Two 110V & two 220V electrical cables were through walls of the Top Doghouse. 3) Two 110V cables were run through the metal roof brackets of the Bottom Doghouse.
Recent events (2)
- — I (O) $500
- — Z (O) $900
More inspections at United Drilling INC.
View United Drilling INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339606642.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.