Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DRAINAGE PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DRAINAGE PRODUCTS, INC. in 100 WEST MAIN ST., HAVILAND, OH 45851 (NAICS 326122). OSHA activity number 339608317.

Watch Drainage Products, INC. — free Get an email when a new federal OSHA severe-injury report for Drainage Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 WEST MAIN ST.
City
HAVILAND
State
OH
ZIP
45851
Mailing
P.O. BOX 97, HAVILAND, OH 45851
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
73
Ownership type
A

5 citations on file for this inspection.

1910.137 B02 VIII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3850.00 · Current $2258.00 Reduced
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-5 and I-6:     a) Drainage Products, Inc. - Haviland, Ohio:  On or about November 29, 2013, the employer did not ensure that electrical protective rubber gloves used by employees were tested at least once every six months after being put into service.  A maintenance employee used the gloves while accessing the inside of the operator control box (480v) to de-energize and re-energize the Corma Inc. manufactured #6 MQR Corrugator (Serial #6271).
Recent events (2)
  • — I (S) $2258
  • — Z (S) $3850

1910.303 B07 IV

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $5390.00 · Current $3876.00 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating:    a) Drainage Products, Inc. - Haviland, Ohio:  On or about January 10, 2014, the employer did not ensure that the operator control box on the Corma Inc. manufactured #6 MQR Corrugator (Serial #6271) was free of damaged/broken parts, in that the power disconnect switch was broken inside of the unit.  This resulted in production, maintenance and supervisory personnel having to remove the protective cover to de-energize and re-energize the equipment, exposing them to electrical hazards, which could result in electrocution, electric shock, and/or arc flash/blast injuries.
Recent events (2)
  • — I (S) $3876
  • — Z (S) $5390

1910.332 B01

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $5390.00 · Current $3876.00 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    a) Drainage Products, Inc. - Haviland, Ohio:  On or about January 10, 2014, the employer did not ensure employees were provided with training on electrical safety-related work practices, which may include topics such as, but not limited to electric shock hazards, arc flash/blast hazards, and protective equipment for the face, hands and body.  Because a power disconnect switch was broken on the Corma Inc. manufactured #6 MQR Corrugator (Serial #6271), employees were required to remove the protective cover on the operator control box to de-energize and re-energize the equipment, exposing them to 480 volts of electricity that could result in electrocution, electric shock and/or arc flash/blast injuries.
Recent events (2)
  • — I (S) $3876
  • — Z (S) $5390

1910.333 A

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:   a) Drainage Products, Inc. - Haviland, Ohio:  On or about January 10, 2014, the employer did not ensure that employees utilized electrical safety related work practices while opening and accessing an operator control box with live or potentially live electrical components (480 volts).  Employees attempting to de-energize and re-energize the Corma Inc. manufactured #6 MQR Corrugator (Serial #6271) were exposed to electrical hazards such as, but not limited to electrocution, electric shock, and/or arc flash/blast injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $5390.00 · Current $0.00 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    a) Drainage Products, Inc. - Haviland, Ohio:  On or about January 10, 2014, the employer did not ensure that employees used protective equipment for their body, hands and face while exposed to electrical hazards.  Employees attempting to de-energize and re-energize the Corma Inc. manufactured #6 MQR Corrugator (Serial #6271) were exposed to electrical hazards such as, but not limited to electrocution, electric shock, and/or arc flash/blast injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5390

View DRAINAGE PRODUCTS, INC.'s full OSHA safety record →

LIPPERT