MARIETTA, GA ·
OSHA Inspection: RJE SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RJE SERVICES in BLDG # 6 1250 POWDER SPRINGS ROAD, MARIETTA, GA 30064 (NAICS 238170). OSHA activity number 339611220.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RJE SERVICES
- Site address
- BLDG # 6 1250 POWDER SPRINGS ROAD
- City
- MARIETTA
- State
- GA
- ZIP
- 30064
- Mailing
- 1249 HARRINGTON ROAD, LAWRENCEVILLE, GA 30044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 3, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) At the multifamily residence, Building 6, 1250 Powder Springs Road, Marietta, GA: Employees using Pneumatic Hitachi Nail Gun, Model: NT 65M2 were not protected from eye injuries while installing siding.
Recent events (1)
- · Z (S) $1600
1926.451 B10
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were modified in order to intermix them and a competent person did not determine that the resulting scaffold was structurally sound: a) Rear of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed an employee installing siding on a residence; to fall hazards of approximately 24 feet while working from an Alum-A-Pole pump jack scaffold with an intermixed Make Shift wood planks/platform component.
Recent events (1)
- · Z (S) $2800
1926.451 C02
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Front of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed an employee installing siding on a residence; to fall hazards of approximately 11 feet while working on an Alum-A-Pole pump jack scaffold without proper footings or base plates. b) Rear of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed employees installing siding on a residence; to fall hazards of approximately 24 feet while working on an Alum-A-Pole pump jack scaffold without proper footings or base plates.
Recent events (1)
- · Z (S) $2800
1926.451 G01
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Front of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed employees installing siding from a working platform of an Alum-A-Pole pump jack scaffold, approximately 11 feet above ground level; as the employee was not wearing personal fall arrest system and neither guard rails or safety nets had been installed. b) Rear of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed employees installing siding from a working platform of an Alum-A-Pole pump jack scaffold, approximately 24 feet above ground level; as the employee was not wearing personal fall arrest system and neither guard rails or safety nets had been installed.
Recent events (1)
- · Z (S) $2800
1926.452 J02
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Font of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed an employee installing siding to a lower level fall hazard of approximately 11 feet while working from an Alum-A-Pole pump jack scaffold that did not have its poles secured at the bottom. a) Rear of building # 6; 1250 Powder Springs Road, Marietta, GA- The employer exposed an employee installing siding to a lower level fall hazard of approximately 24 feet while working from an Alum-A-Pole pump jack scaffold that did not have its poles secured at the bottom.
Recent events (1)
- · Z (S) $2000
1926.501 B13
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the roof of building # 6; 1250 Powder Springs Road, Marietta, GA- An employee, installing siding and sheathing materials without fall protection was exposed to a fall of approximately more than 25 feet.
Recent events (1)
- · Z (S) $2800
1926.503 C03
- Issued
- Jun 3, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. a) At building # 6; 1250 Powder Springs Road, Marietta, GA- Employees installing siding and sheathing materials onto a multifamily residence were exposed to a lower level fall hazard of approximately more than 25 feet, in that; the employees were working without fall protection; hey were previously trained in fall all protection and did not retained the requisite or skill of proper use personal fall arrest systems. Employees failed to retained and understand the procedures to be followed to minimize the fall hazards.
Recent events (1)
- · Z (S) $2800
More inspections at RJE Services
View RJE Services's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339611220.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.