Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARRAH'S RESORT SOUTHERN CALIFORNIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARRAH'S RESORT SOUTHERN CALIFORNIA in 777 HARRAH'S RINCON WAY, VALLEY CENTER, CA 92082 (NAICS 721120). OSHA activity number 339611329.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harrah'S Resort Southern California — free Get an email when a new federal OSHA severe-injury report for Harrah'S Resort Southern California is published. One employer, no account, unsubscribe in one click.
Site address
777 HARRAH'S RINCON WAY
City
VALLEY CENTER
State
CA
ZIP
92082
Mailing
777 HARRAH'S RINCON WAY, VALLEY CENTER, CA 92082
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
1600
Ownership type
A

7 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 17, 2014
Abate by
Jun 4, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  In the 20,000 square foot warehouse on or about March 5, 2014, and at times prior thereto, one exit door consisted of a 10 by 10 foot roll up door that led to the outside dock. Door leaves or grilles were were not operable from within the space without the use of any special knowledge or effort as the operator needed to know a chain hanging near the door could be used to manually raise the door or a button near the door would start an electric motor to raise the door.
Recent events (3)
  • — F (S) $2550
  • — C (S) $2550
  • — Z (S) $2550

1910.36 E01

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 17, 2014
Abate by
Jun 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route:  In the 20,000 square foot warehouse on or about March 5, 2014, and at times prior thereto, one exit door consisted of a 10 by 10 foot roll up door that led to the outside dock. The other exit consisted of a side hinged door to an interior hallway about 150 feet from the rollup door.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 17, 2014
Abate by
Apr 25, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in Sec. 1910.6:  Inside the warehouse next to the rollup door to the exterior dock on or about March 5, 2014, and at times prior thereto, a helium gas bottle was not stored in accordance with CGA Pamphlet P-1-1965 paragraph 3.3.8 which states in part: Protect cylinders from any object that will produce a cut or other abrasion in the surface of the metal. Do not store cylinders near elevators or gangways, or in locations where heavy moving objects may strike or fall on them. The helium gas bottle bottle was subject to being struck by forklifts that were driven through the rollup door opening. The helium was used to fill balloons for events at the casino and hotel.
Recent events (3)
  • — F (S) $2550
  • — C (S) $2550
  • — Z (S) $2550

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 17, 2014
Abate by
Apr 25, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.134(c)(2)(i): When the employer determined that any voluntary respirator use was permissible, the employer did not provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"):    Inside the wood shop on or about March 5, 2014, and at times prior thereto, employees were not provided with   the information contained in Appendix D of this section, and the employer allowed the employees to wear N95 respirators made by 3M Corporation. Employees employees wore the dust masks when they used power saws to cut fir wood, plywood, melomine particle board, and plexiglass.
Recent events (3)
  • — F (O) $2550
  • — C (S) $2550
  • — Z (S) $2550

1910.178 M05 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 17, 2014
Penalty
Initial $2,168 · Current $2,168
29 CFR 1910.178(m)(5)(i): When a powered industrial truck was left unattended, load engaging means were not fully lowered, controls shall be neutralized, power shall be shut off, and brakes set:   On the warehouse dock on or about March 5, 2014, the tines were not lowered all the way to the floor on a Towmotor forklift, model number TGP25. The tines of the forklift were about 4 to 7 inches above the floor. The operator of the lift was not within 25 feet of the lift as he was inside the warehouse. The warehouse manager said the forklift was used to move pallets of decorative items for the hotel rooms.
Recent events (3)
  • — F (S) $2168
  • — C (S) $2168
  • — Z (S) $2168

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Apr 17, 2014
Abate by
Apr 25, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:    Inside the wood shop on or about March 5, 2014, and at times prior thereto, a surge bar designed to power electronic equipment was used to power a 110 VAC Ryobi band saw. The saw was used to cut plexiglass and wood for tabletops.
Recent events (3)
  • — F (O) $2550
  • — C (S) $2550
  • — Z (S) $2550

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
Apr 17, 2014
Abate by
Apr 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about was introduced into their work area:  At the facility on or about March 5, 2014, and at times prior thereto, employees had not been made aware of the new Globally Harmonized System for dealing with hazardous chemicals in the workplace. Specifically, they were not aware that new warning labels on containers will have standardized pictograms to identify the hazards of the chemicals, and that material data sheets with a standardized format and warnings will replace the current material safety data sheets.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Harrah'S Resort Southern California's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339611329.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.